Motorola operation manual Specifications, SG2-DRT-3X Dwdm Models, Parameter Specification

Page 12

12STARLINE

Specifications

Specifications are valid over the given bandpass and operating temperature range of 40°F to +140°F (40°C to +60°C). Specifications stated are typical unless otherwise noted, and are subject to change. Refer to the Motorola BCS Web site or contact your account representative for the latest specifications.

Parameter

Specification

Wavelengths

See following table

RF bandwidth

5 MHz to 42 MHz

Number of input channels

3

Input level

15 dBmV total power per channel

Input impedance

75 ohms

Input return loss

>16 dB

Output power

 

DWDM

8 dBm (6.3 mW)

CWDM

3 dBm (2.0 mW)

Noise Power Ratio

40/11 dB (dB over dynamic range)

Power input

+24 VDC

Power consumption

0.6 amps worst case

Operating temperature range

−40°C to +85°C

Storage temperature range

−40°C to +85°C

Dimensions

3.5” (H) × 2” (W) × 6” (D)

Weight

1.8 lbs

SG2-DRT-3X DWDM Models

Model

Wavelength (nm)

Model

Wavelength (nm)

 

 

 

 

SG2-DRT-3X-CH20

1561.42

SG2-DRT-3X-CH32

1551.72

 

 

 

 

SG2-DRT-3X-CH21

1560.61

SG2-DRT-3X-CH33

1550.92

 

 

 

 

SG2-DRT-3X-CH22

1559.79

SG2-DRT-3X-CH34

1550.12

 

 

 

 

SG2-DRT-3X-CH23

1558.98

SG2-DRT-3X-CH35

1549.32

 

 

 

 

SG2-DRT-3X-CH24

1558.17

SG2-DRT-3X-CH38

1546.92

 

 

 

 

SG2-DRT-3X-CH25

1557.36

SG2-DRT-3X-CH43

1542.94

 

 

 

 

SG2-DRT-3X-CH26

1556.56

SG2-DRT-3X-CH45

1541.35

 

 

 

 

SG2-DRT-3X-CH27

1555.75

SG2-DRT-3X-CH47

1539.77

 

 

 

 

SG2-DRT-3X-CH28

1554.94

SG2-DRT-3X-CH49

1538.19

 

 

 

 

SG2-DRT-3X-CH29

1554.13

SG2-DRT-3X-CH51

1536.61

 

 

 

 

SG2-DRT-3X-CH30

1553.33

SG2-DRT-3X-CH53

1535.04

 

 

 

 

SG2-DRT-3X-CH31

1552.52

SG2-DRT-3X-CH55

1533.47

 

 

 

 

SG2-DRT-3X-CH30

1553.33

SG2-DRT-3X-CH57

1531.90

 

 

 

 

SG2-DRT-3X-CH31

1552.52

SG2-DRT-3X-CH59

1530.33

 

 

 

 

SG2-DRT-3X Installation Sheet

Image 12
Contents SG2-DRT-3X Installation Sheet Related Documentation Document ConventionsBefore You Begin AsteriskSG2-DRT-3X block diagram SG2-DRT-3X transmitterKeyFeature DescriptionSG2-DRT-3X side view and laser warning label Installing the SG2-DRT-3X in the SG2440 Node SG2440-DR-3X return configurationSG2440-DR-3X return board SG2440 lid Illustrates a properly installed and cabled SG2-DRT-3X Installing the SG2-DRT-3X in the SG2000 Node SG2-DRT-3X cabling for combined configurationSG2 ICS board SG2-DRT-3X Installation Sheet Illustrates the ICS boardSG2000 optical transmitter B and a locations JP1SG2-DRT-3X installed in SG2000 Page Specifications Parameter SpecificationSG2-DRT-3X Dwdm Models ModelSG2-DRT-3X Cwdm Models If You Need HelpModel Description Special Symbols That Might Appear on the Equipment EMC Standards