Motorola operation manual KeyFeature, Description, SG2-DRT-3X side view and laser warning label

Page 3

STARLINE3

Table 1 provides information on the user-related features of the SG2-DRT-3X.

KeyFeature

1OPTICAL POWER (1 V/mW)

Description

This test point enables monitoring of the optical output level of the module. The nominal scale factor is 1.0 V/mW (6.3 V equates to 8 dBm). The optical power test point does not track changes in optical power due to the laser tracking error.

2

3

4

5

F

A

U

L O

T N

ALARM

I

N

P

U

T

A

I

N

P

U

T

B

A red (FAULT) LED indicates that the laser output power is below normal limits.

A green LED (ON) indicates the transmitter is enabled.

Because the laser output requires a short period of time to stabilize, it is normal for neither LED to illuminate for approximately 10 seconds. The module must be enabled for the fault indicator to function.

This MCX connector provides the SG2-DRT-3X with channel A RF input through a cable connection to the node lid board in an SG2440 or the E-pack in an SG2000.

This MCX connector provides the SG2-DRT-3X with channel B RF input through a cable connection to the node lid board in an SG2440 or the E-pack in an SG2000.

Channel C RF input is provided by direct connection of the node lid board with the D-type connector on the bottom of the SG2-DRT-3X.

This SC/APC-type connector provides optical output from the SG2-DRT-3X.

Figure 3 illustrates a side view of the SG2-DRT-3X and indicates the laser warning label.

Figure 3

SG2-DRT-3X side view and laser warning label

DANGER

INVISIBLE LASER RADIATION WHEN OPEN

PEAK POWER 10 mW

CLASS I LASER PRODUCT

THIS PRODUCT COMPLIES WITH 21CFR

CHAPTER 1 SUBCHAPTER J

SG2-DRT-3X Installation Sheet

Image 3
Contents Asterisk SG2-DRT-3X Installation SheetRelated Documentation Document Conventions Before You BeginSG2-DRT-3X transmitter SG2-DRT-3X block diagramKeyFeature DescriptionSG2-DRT-3X side view and laser warning label Installing the SG2-DRT-3X in the SG2440 Node SG2440-DR-3X return configurationSG2440-DR-3X return board SG2440 lid Illustrates a properly installed and cabled SG2-DRT-3X SG2-DRT-3X cabling for combined configuration Installing the SG2-DRT-3X in the SG2000 NodeIllustrates the ICS board SG2 ICS board SG2-DRT-3X Installation SheetJP1 SG2000 optical transmitter B and a locationsSG2-DRT-3X installed in SG2000 Page Model SpecificationsParameter Specification SG2-DRT-3X Dwdm ModelsSG2-DRT-3X Cwdm Models If You Need HelpModel Description Special Symbols That Might Appear on the Equipment EMC Standards