Adder Technology X50 manual Further information, Getting assistance, Troubleshooting

Page 15

Further information

Getting assistance

Adder Technology website – www.adder.com

Check the Support section of our website for the latest solutions and driver files.

Email – support@adder.com

Fax in the UK: 01954 780081

in the US: +1 888 275 1117

Phone in the UK: 01954 780044 in the US: +1 888 932 3337

Troubleshooting

Status indicators

The green and yellow indicators built into the link connectors on each module provide useful feedback regarding the connection and power status:

During startup (of the local module)

One very short yellow flash: no valid DDC information available from a locally connected video monitor, no changes made to stored DDC information.

Single yellow flash: DDC information being read from a locally connected video monitor, but no changes made to stored DDC information.

Rapid yellow flash for 2 to 3 seconds, followed by single flash: New DDC information being read and stored from a locally connected video monitor.

Two yellow flashes - Checksum error prior to copying - no information will be programmed.

Three yellow flashes - Too much data to fit into the module - the module can hold a maximum of two pages of DDC information.

Rapid yellow flashing followed by four flashes - data was lost during copying - the default data was substituted. Repeat the power on process.

Rapid yellow flashing followed by five flashes - Checksum error during copying - the default data was substituted. Repeat the power on process.

During operation (either module)

Continual yellow: Valid CATx link to other module sensed.

Continual green: Correct power input sensed.

Green flashes: Power input too low for normal operation. In the case of the local module, this may be because the USB connection is unable to provide sufficient power. In these cases, an external power supply should be used with the local module.

Important

Do not attach a USB hub to the X50 remote, nor plug the X50 local module into another USB hub. To do so will reduce the maximum cable length over which the system will extend USB; also, some USB hubs may not provide enough power to operate the local unit.

informationfurther operation installation welcome contents

14

Image 15
Contents AdderLink X50 USB Contents Introduction WelcomeSupplied items Installation welcome contentsOptional items Installation ConnectionsMounting Connections at the local module ContentsLocal module power See the Important note on Connections at the remote moduleTo speakers User Dual user configurationDDC indications Video display DDC informationTo adjust video sharpness Video sharpness adjustmentPeripheral operation OperationGeneral use Dual user arbitrationTroubleshooting Further informationGetting assistance Safety information WarrantyCanadian Department of Communications RFI statement Radio Frequency EnergyEuropean EMC directive 89/336/EEC FCC Compliance Statement United StatesHoe Huat Industrial Building