Accton Technology Workgroup-3726M manual Power and Cooling Problems, Installation

Page 22

Quick Installation Guide

Symptom

Cause

Solution

Power indicator

Power outlet, power

Check the power outlet by plugging in another device

does not light up

cord, or internal power

that is functioning properly. Check the power cord with

after power on.

supply may be

another device. If these measures fail to resolve the

 

defective.

problem, contact your Accton distributor.

Link indicator

Network interface (e.g.,

Verify that the switch and attached device are

does not light up

a network adapter card

powered on. Be sure the cable is plugged into both the

after making a

on the attached

switch and corresponding device. Verify that the

connection.

device), network cable,

proper cable type is used and its length does not

 

or switch port may be

exceed specified limits. Check the adapter on the

 

defective.

attached device and cable connections for possible

 

 

defects. Replace the defective adapter or cable if

 

 

necessary.

Mgmt indicator

A Management Module

Check that the Management Module is correctly

does not light up

is not installed

installed in the upper slot on the switch rear panel (at

after power on.

correctly, or may have

least one Management Module is required in a switch

 

failed.

stack). Test the Management Module by installing it in

 

 

another switch unit. If these measures fail to resolve

 

 

the problem, contact your Accton distributor.

Module 1/2 Status

A optional module is

Check that the module is correctly installed in one of

indicator does not

not installed correctly,

the two lower slots on the switch rear panel. Test the

light up after power

or may have failed.

module by installing it in another switch unit. If these

on.

 

measures fail to resolve the problem, contact your

 

 

Accton distributor.

Switch ID LCD

The switch stack has

Reset the stack by powering off each switch unit in the

does not display a

not initiated properly.

stack and then powering them back on. Check all

stable unit number.

 

Stacking Modules are installed correctly in the

 

 

lower-left slot on the rear panel of each switch. Check

 

 

that all stacking cables are connected correctly. If

 

 

these measures fail to resolve the problem, contact

 

 

your Accton distributor.

Power and Cooling Problems

If the power indicator does not turn on when the power cord is plugged in, you may have a problem with the power outlet, power cord, or internal power supply as explained in the previous section. However, if the unit powers off after running for a while, check for loose power connections, power losses or surges at the power outlet, and verify that the fans on the right side of the unit are unobstructed and running prior to shutdown. If you still cannot isolate the problem, then the internal power supply may be defective. In this case, contact your Accton distributor for assistance.

Installation

Verify that all system components have been properly installed. If one or more components appear to be malfunctioning (e.g., the power cord or network cabling), test them in an alternate environment where you are sure that all the other components are functioning properly.

14

Image 22
Contents CheetahSwitch Workgroup-3726M Quick Installation Guide Page CheetahSwitch Workgroup-3726M On-line Registration Accton Technology Corporation Limited Warranty Contents Optional Hardware Modules Introduction Package Contents Installing the SwitchDescription of Hardware Mounting the Switch Installing the SwitchInstalling a Management Module Installing Optional Media and Stacking ModulesConnecting to the Stack’s Backplane Connecting the Switch System Making a Connection to an RJ-45 PortConnecting to a 100BASE-FX Port Powering On the Switch Verifying Port Status Verifying System OperationApplications Product Specifications Base UnitSwitching Criteria ModulesTroubleshooting Diagnosing Switch IndicatorsPower and Cooling Problems InstallationPort and Cable Assignments RJ-45 Port DescriptionCanada Department of Communications Class a EMI CertificationFCC Class a Certification USA Bsmi Class a Taiwan Vcci Class a Compliance JapanCE Mark Declaration of Conformance for EMI and Safety EEC Warnhinweis Faseroptikanschlüsse Optische Sicherheit Safety ComplianceUnderwriters Laboratories Inc. USA Wichtige Sicherheitshinweise Germany Optional Hardware Modules Page AC-ES3726M E012002-R01 F2.476 150200008100A