Installing the Ribbon Cassette

 

Panel open button

Panel cover

(at both sides of the unit)

 

Key hole

Panel house

Ribbon cassette

Print head

Print head

Ribbon mask

1 Unlock the unit. While holding down the panel, open buttons at both sides of the unit, and lift the panel cover away from you.

2 Turn the knob on the cassette in the arrow-indicated direction to make the ribbon taut.

To insert the ribbon cassette inside the unit, lift the panel house away from you first. Then thread the ribbon between the ribbon mask and the print head. Slide the latch on the lower side of the cassette into projections on the unit. Then let the cassette snap into place.

When having difficulty inserting the ribbon, insert it while turning the knob.

Make sure that the ribbon is placed between the print head and the ribbon mask as illustrated in the figure at left.

3 Put the panel cover on the hook at the back of the unit. Lower it toward this side to close and lock the unit.

Panel cover

Ribbon

5

Image 7
Contents Simplex Page Table of Contents Signs PrecautionsFeatures Hour indication Current time AM or PM Current date AccessoriesFeatures KeysRibbon cassettePanel open button Installing the Ribbon CassetteEnvironmental Conditions Wall MountingMount the wall mount fittings as shown on the right Daily Operations Key hole Panel house Display SettingPreparation for setting To prepare for setting Unlock the unit. While holding downMonthly Closing Setting the Pay PeriodToday is printed on the second line from the top Weekly ClosingToday is printed on the ninth line from the top Bi-Weekly ClosingTo set the number, the digits must When you want to apply 12 hourCheck the settings on the display Second button from the left12Hr. SU MO TU WE TH FR SA 100 Day advance time Setting the Day Advance TimeCase of the day advance time 730 a.m Daylight saving time function Setting the Daylight Saving Time D.S.TStart date of D.S.T /60 How to Cancel D.S.T. Settings Setting the Time Table Program Time to be set Print color 00 Black 01 Red3Print column To set P-01 shown in the tableErase under MO MinuteErase under TU Staying lit up 1/100 Erase under MO SALight up External 1/60 time signal 1/100Make the bars Under MO-SAIndication at To check program settingsPress Select to cause EXT. Alarm to light up Setting Number of Seconds for External Time SignalResetting Connecting to AN External Time Signal Installing the Ni-Cd Batteryoptional Connection SpecificationsExternal time signal Temperature -5 to + 45CTime Card Specifications Weekly Card Bi-Weekly Card 1406-9806