Preliminary Information
AMD Athlon™ Processor Model 4 Revision Guide | 23614K |
11 PLL Overshoot on
Products Affected. A4, A5, A6, A7, A9
Normal Specified Operation. The AMD Athlon processor model 4 PLL should return to the normal operating frequency when reconnecting to the system bus after a disconnect where the PLL was reduced to a lower operating frequency.
Potential Effect on System. The system hangs.
Suggested Workaround. The event can be avoided through BIOS manipulation of the reconnect timing using the CLK_CTRL MSR. (See AMD Athlon™ and AMD Duron™ Processor CLK_CTRL MSR Settings, order# 24478, for exact values.)
The time for the PLL to overshoot can be greatly shortened to reduce it to a very small time period that does not enable the failure, and the time between the rampup and the reconnect to the system bus can be increased such that a failure in the compensation circuit has enough time to recover before reconnecting to the bus.
Resolution Status. Fix planned for a future revision.
8