Belkin AP41300fc12-BLK user manual Step Program the Outlet Banks

Page 9

Hookup and Installation

Step 2

Program the Outlet Banks

Each outlet bank on the rear panel of the Power Console is programmable. Using the slide switches on the rear panel, you can program the outlets for switched or unswitched, and for delay or always-on (no delay) (Fig. 2). You can also determine the length of the delay (5, 10, or 15 seconds).

A. Outlet Banks Always-On (unswitched): For components that need to retain memory or other settings (DVRs, satellite receivers, VCRs), set the top slide switch to “Always ON” (Fig. 2a). These outlet banks will always supply power when the Power Console is plugged into the wall.

B.Outlet Banks Switched On (no delay): Set the top slide switch to “Switched”. Make sure that the lower slide switch is set to “No Delay” (Fig. 2b). The outlet banks will be immediately powered-on when the Power Console is switched-on by pressing the “Switched” button on the front of the unit. Switched outlets can also be switched-on by external remote signal (see page 15). These outlets will remain powered-on for a short period of time after switching them off depending on the “Delay Time” setting (see “Delay Time Switch” below).

C.Outlet Banks Switched On After Delay: You may find it necessary to program your outlets to switch on after a delay. Once the delay is set, the outlets will be powered-on after the outlets that are set for “no delay” have powered-on. They will then power-off in reverse sequence: “delay” outlets will power-off first and “no delay” outlets will power-off last. This is useful to avoid the loud and occasionally damaging “thump” created when the amplifier voltage is stabilizing.

a.Set the top slide switch to “Switched” and the bottom slide switch to “Delay” (Fig. 2c).

b.Repeat this for each bank that you want to be switched on after a delay.

c.Press the “Switched” button on the front of the Power Console to activate all of the switched outlets

Note: The delay can only be set on “Switched” outlets.

D.Delay Time Switch: This switch sets the length of delay for all outlet banks that are programmed as “Switched” and “Delay”. Set the delay time by selecting 5, 10, or 15 seconds (Fig. 2d). 15 seconds is the recommended delay time for tube amplifiers.

Belkin Power Console

8

Image 9
Contents Manuel d’utilisation Table of Contents Introduction Safety Precautions Package Contents Power Console Features Power Console Features Optional Mounting your Power Console Hookup and InstallationStep Program the Outlet Banks Hookup and Installation Hookup and Installation Step Connect Video Components to the Video Filter Bank Hookup and Installation Step Connect High-Current Audio Filter Bank Step Connect your Coaxial-Cables/DSS Lines Central LCD Control Panel OperationAuxiliary Power Outlet Power Console is not providing power TroubleshootingCross-Wired indicator is lit Ground Fault indicator is litGlossary of Power Terms Belkin Connected Equipment Warranty Belkin Connected Equipment Warranty Belkin Connected Equipment Warranty Table des matières Image claire Son pur Belkin Mesures de sécurité Contenu de l’emballage Fonctions de la console d’alimentation Fonctions de la console d’alimentation Étape 1 optionnel Montage de la console d’alimentation Branchement et installationÉtape Programmation des banques de fiches Branchement et installation Branchement et installation Belkin Power Console Console dalimentation Belkin Étape Branchement du filtre audio à haute tension Banque Étape Branchement des câbles coaxiaux et DSS Panneau de contrôle ACL central FonctionnementPrise de courant auxiliaire La console d’alimentation nalimente pas les composants DépannageLe voyant de mise à la terre défectueuse est allumé Le voyant Cross-Wired est alluméGlossaire délectricité Garantie sur les appareils branchés de Belkin Garantie sur les appareils branchés de Belkin Belkin International, 501 W. Walnut St., Compton CA Page Belkin Tech Support US 800-223-5546, ext