RS232 (continued)
Following the header, a comma is used to delimit the header from the command. All the commands with their descriptions are listed below. All the text strings are terminated with a carriage return (0x0d or 13). Maximum command string length is 250 characters.
OPERATION COMMANDS (Used for day-to-day operation)
COMMAND | OPTIONS OR RANGE | DESCRIPTION |
A# | Input Aspect Ratio – for all sources | |
|
|
|
B# | Brightness | |
|
|
|
C# | Contrast | |
D# | Detail | |
|
|
|
DVI |
| DVI Input |
EXT |
| |
|
|
|
FST |
| Report Current System Status |
HELP |
| Displays full list of commands for this unit |
|
|
|
K# | Color | |
|
|
|
OFF |
| Power OFF |
|
|
|
ON |
| Power ON |
|
|
|
P# | Recall Preset | |
|
|
|
PM# | Advanced Color System | |
|
|
|
PY |
| PassThru Transcoded Input |
|
|
|
R |
| RGB input |
|
|
|
ST |
| Report Current Status |
|
|
|
T# | Tint | |
|
|
|
TP# | 0=Off |
|
| 1=100% Color Bars |
|
| 2=Reverse Color Bars |
|
|
| |
| 4=Luma Ramp |
|
| 5=Cb Ramp |
|
| 6=Cr Ramp |
|
| 7=Green |
|
| 8=Red |
|
| 9=Blue |
|
| 10=Convergence |
|
| 11=Active Boarder |
|
| 12=Multiburst |
|
| 13=100% Window |
|
| 14=PLUGE Test Pattern Selection |
|
|
|
|
TPHELP |
| Display Test Pattern Help |
V |
| Video input |
X |
| YCrCb input |
|
|
|
Y |
| |
|
|
|
14