10.TINT Gain Data Function
The external control equipment changes the TINT gain data of the PlasmaSync 4210W.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag  | 01H  | 
DATA01: TINT Gain Flag  | 05H  | 
DATA02: TINT Gain  | EAH:   | 
FFH: 
00H: 0
01H: +01
16H: +22
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00:  | USER PICTURE Gain Flag  | 01H  | 
DATA01:  | TINT Gain Flag  | 05H  | 
11.SHARPNESS Gain Data Function
The external control equipment changes the SHARPNESS gain data of the PlasmaSync 4210W.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag  | 01H  | 
DATA01: SHARPNESS Gain Flag  | 06H  | 
DATA02: SHARPNESS Gain  | F0H:   | 
FFH: 
00H: 0
01H: +01
10H:+16
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00:  | USER PICTURE Gain Flag  | 01H  | 
DATA01:  | SHARPNESS Gain Flag  | 06H  | 
12.CONTRAST Gain Data Function
The external control equipment changes the CONTRAST gain data of the PlasmaSync 4210W.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag  | 01H  | |
DATA01: CONTRAST Gain Flag  | 07H  | |
DATA02: CONTRAST Gain  | 00H : 0  | |
  | 
  | 
  | 
  | 34H: +52  | |
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00:  | USER PICTURE Gain Flag  | 01H  | 
DATA01:  | CONTRAST Gain Flag  | 07H  | 