Magenta XR2000 setup guide Appendix C. Setting Sync Mode, Jumper Setting JP10 JP11 JP12

Page 18

MAGENTA MULTIVIEW™ SERIES

Appendix C. Setting Sync Mode

The XR2000 has the capability for fixed and agile sync. The default sync mode setting is for agile sync which replicates the source sync polarity signals. However some displays require a fixed sync polarity that is not possible to change at the video source. The following details jumper settings to change the sync polarity of the horizontal and vertical sync signals (Note that jumpers JP11 and JP12 have no affect in agile mode):

Jumper Setting

JP10

JP11

JP12

 

 

 

 

Fixed Sync

IN

-

-

 

 

 

 

Agile Sync (default)

OUT

-

-

 

 

 

 

Horizontal Sync

-

IN

-

Positive

 

 

 

Horizontal Sync

-

OUT

-

Negative

 

 

 

 

 

 

 

Vertical Sync

-

-

IN

Negative

 

 

 

 

 

 

 

Vertical Sync

-

-

OUT

Negative

 

 

 

 

 

 

 

Sync Mode jumpers

JP10, JP11, JP12

168

Image 18
Contents MultiView Magenta ResearchBy Magenta Research All rights reserved European Union Declaration of Conformity Contents Specifications Equipment You May Also Need IntroductionOverview Compatible CablingData Mode Configuration Cabling ConsiderationsMaking the Connections Connections on the SINGLE-PORT VGA/AUDIO Connections on the SINGLE-PORT VGA SA and SAP SA & SAP connectionsVideo Adjustment Cable Distance Compensation SettingsSkew Compensation Settings Image Adjustment Utility-SkewProblem TroubleshootingCommon Problems Solution113 Table A-1. HD15 video connector Appendix A. Cabling PinoutsTable A-2. Phoenix Connection Table A-3. DB9 Male Serial connector Table A-4. T568B CAT5 pinoutAppendix B. XR2000 Configuration Settings 157 Appendix C. Setting Sync Mode Jumper Setting JP10 JP11 JP12Appendix D. Skew Module Figure D-1Appendix E. Rackmounting Units Figure E-1. Receiver Mounting BracketAppendix F. Pollable Serial Mode Appendix F. Pollable Serial Mode Address Chart Appendix F. Pollable Serial Mode Address Chart Cont Magenta Research