Magenta XR2000 setup guide Appendix F. Pollable Serial Mode

Page 21

APPENDIX F: Pollable Serial Mode.

Appendix F. Pollable Serial Mode

The SAP pollable serial daisychainable receivers with video, audio and RS232 serial feature the ability to open a bi-directional session between a pollable transmitter and a single pollable receiver in a daisychain installation.

Each pollable receiver must have a unique address set first. Once this has been done, a special command (discussed below) is sent to the transmitter to specify the receiver to open a session with. Once this has been done, serial communication can occur between the RS232 source and display. The transmitter is always addressed 0.

If an address of 0 is sent, the RS232 commands will be broadcast to all receivers.

The following details the installation and setup procedure.

To set the receiver address requires that each internal serial audio daughterboard in the receiver have a unique address set. This is done via an 8 position dipswitch. Use the following chart to determine the proper switch addresses. All receivers must have a unique address. It is recommended to write the address on each receiver once this step has been completed. It is also recommended to keep a list of receiver addresses and locations to make it easier to determine which receiver/display is desired to communicate with.

1)Remove the top cover assembly of the receiver

2)Locate the 8 position dipswitch on the internal daughterboard assembly and using the following chart, set the receiver address.

3)Replace cover assembly and install unit.

4)See below on using pollable serial mode.

In order to utilize the pollable serial mode in normal operation and connect to individual receivers, a special command needs to be sent to the transmitter in order to establish a session between transmitter and receiver.

Follow the steps below to do this (must be done from serial control application in use).

1)To establish a bi-directional RS232 session with a specific receiver, the transmitter needs the receivers address set. To do this send a CTRL-D <ID> carriage return, where <ID> is the receiver address (between 1-254)

2)To broadcast serial commands to all receivers, set <ID> to 0.

3)To disable serial communication to all receivers, set <ID> to 255 (to enable serial communication again, simply set <ID> to a receiver address).

Once a transmitter has the correct ID set, normal bi-directional communication can occur between transmitter and intended receiver.

1921

Image 21
Contents Magenta Research MultiViewBy Magenta Research All rights reserved European Union Declaration of Conformity Contents Specifications Overview IntroductionEquipment You May Also Need Compatible CablingData Mode Configuration Cabling ConsiderationsMaking the Connections Connections on the SINGLE-PORT VGA/AUDIO SA & SAP connections Connections on the SINGLE-PORT VGA SA and SAPCable Distance Compensation Settings Video AdjustmentImage Adjustment Utility-Skew Skew Compensation SettingsCommon Problems TroubleshootingProblem Solution113 Table A-1. HD15 video connector Appendix A. Cabling PinoutsTable A-2. Phoenix Connection Table A-4. T568B CAT5 pinout Table A-3. DB9 Male Serial connectorAppendix B. XR2000 Configuration Settings 157 Jumper Setting JP10 JP11 JP12 Appendix C. Setting Sync ModeFigure D-1 Appendix D. Skew ModuleFigure E-1. Receiver Mounting Bracket Appendix E. Rackmounting UnitsAppendix F. Pollable Serial Mode Appendix F. Pollable Serial Mode Address Chart Appendix F. Pollable Serial Mode Address Chart Cont Magenta Research