Magenta XR2000 setup guide Appendix D. Skew Module, Figure D-1

Page 19

APPENDIX D: Skew Compensation Module.

Appendix D. Skew Module

The XR2000 receivers have an optional skew compensation module that can be installed or removed.

To install the skew compensation module:

1Remove top cover.

2Remove the 3 jumpers from J16 pins 1-2, 4-5, 7-8.

4Insert the Skew assembly onto the XR series PCB using 11 pin headers J16 and J17.

5The correct orientation of the skew board is to place the side with the Magenta logo into header J17.

6Reassemble unit.

Removal is the opposite of the above. Ensure 3 jumpers are installed in locations shown in Figure D-1.

Figure D-1.

Skew module placement on headers J16/J17.

J17

Install 3 jumpers on J16 in positions 1-2, 4-5, 7-8 as shown if skew board is removed.

179

Image 19
Contents Magenta Research MultiViewBy Magenta Research All rights reserved European Union Declaration of Conformity Contents Specifications Compatible Cabling IntroductionOverview Equipment You May Also NeedCabling Considerations Data Mode ConfigurationMaking the Connections Connections on the SINGLE-PORT VGA/AUDIO SA & SAP connections Connections on the SINGLE-PORT VGA SA and SAPCable Distance Compensation Settings Video AdjustmentImage Adjustment Utility-Skew Skew Compensation SettingsSolution TroubleshootingCommon Problems Problem113 Appendix A. Cabling Pinouts Table A-1. HD15 video connectorTable A-2. Phoenix Connection Table A-4. T568B CAT5 pinout Table A-3. DB9 Male Serial connectorAppendix B. XR2000 Configuration Settings 157 Jumper Setting JP10 JP11 JP12 Appendix C. Setting Sync ModeFigure D-1 Appendix D. Skew ModuleFigure E-1. Receiver Mounting Bracket Appendix E. Rackmounting UnitsAppendix F. Pollable Serial Mode Appendix F. Pollable Serial Mode Address Chart Appendix F. Pollable Serial Mode Address Chart Cont Magenta Research