Crown CTS 4200, CTS 8200 operation manual Welcome, How to Use This Manual, Features

Page 5

CTs Multi-Channel Power Amplifiers

CTs 4200

Dual

Maximum Average Power

in watts with 0.1% THD.

4 Channels Driven

1 kHz

20

Hz–20 kHz

4-ohm (per ch.)

260W

 

215W

8-ohm (per ch.)

200W

 

190W

70V (per ch.)

220W

 

220W*

1 Channel Driven

1 kHz

20

Hz–20 kHz

4-ohm (per ch.)

270W

 

225W

8-ohm (per ch.)

220W

 

210W

70V (per ch.)

250W

 

245W*

Bridge-Mono

 

 

 

2 Channel-Pairs Driven

1 kHz

20

Hz–20 kHz

8-ohm (per ch. pair)

520W

 

430W

16-ohm (per ch. pair)

400W

 

380W

100V (per ch. pair)

220W

 

220W*

1 Channel-Pair Driven

1 kHz

20

Hz–20 kHz

8-ohm (per ch. pair)

560W

 

450W

16-ohm (per ch. pair)

440W

 

420W

100V (per ch. pair)

250W

 

245W*

* Constant Voltage full bandwidth power ratings support 100Hz - 20kHz due to automatic High-Pass Filters.

CTs 8200

Dual

Maximum Average Power

in watts with 0.1% THD.

8 Channels Driven

1 kHz

20

Hz–20 kHz

4-ohm (per ch.)

200W

 

175W

8-ohm (per ch.)

160W

 

155W

70V (per ch.)

200W

 

185W*

1 Channel Driven

1 kHz

20 Hz–20 kHz

4-ohm (per ch.)

270W

 

230W

8-ohm (per ch.)

220W

 

220W

70V (per ch.)

250W

 

230W*

Bridge-Mono

 

 

 

4 Channel-Pairs Driven

1 kHz

20 Hz–20 kHz

8-ohm (per ch. pair)

400W

 

350W

16-ohm (per ch. pair)

320W

 

310W

100V (per ch. pair)

200W

 

185W*

1 Channel-Pair Driven

1 kHz

20 Hz–20 kHz

8-ohm (per ch. pair)

540W

 

460W

16-ohm (per ch. pair)

440W

 

440W

100V (per ch. pair)

250W

 

230W*

* Constant Voltage full bandwidth power ratings support 100Hz - 20kHz due to automatic High-Pass Filters.

Operation Manual

1 Welcome

Building on the foundation of the Com-Tech®Series, Crown’s CTs Series offers new flexibility and value for installed sound applications. The Com-Tech Series were the first to offer inde- pendent selection of high- and low-impedance operation for a specific channel, and CTs Series amplifiers continue that tradition, with power levels and features carefully chosen to perfectly integrate into fixed install design requirements.

Modern power amplifiers are sophisticated pieces of engineering capable of producing extremely high power levels. They must be treated with respect and correctly installed if they are to provide the many years of reliable service for which they were designed.

In addition, CTs Series amplifiers include a number of features which require some expla- nation before they can be used to their maxi- mum advantage.

Please take the time to study this manual so that you can obtain the best possible service from your amplifier.

1.1 Features

New Crown® Switching Power Supply for reduced weight.

High power-density, with eight channels in a 3U chassis and four channels in a 2U chassis.

Selectable constant-voltage (70V/100V) or low-impedance (8/4 ohm) operation for each channel pair.

FIT (Fault Isolation Topology) circuitry isolates faults within affected channels.

35 Hz High-Pass Filter (70 Hz in CTs 4200) is automatically inserted when the channel pair is set for constant-voltage operation. (corner frequency may be changed as a service option).

Accepts new MC accessory modules that tailor the amplifier to suit specific applica-

tions. Modules available for remote VCA level control and IQ System® Control.

Comprehensive array of indicators includ- ing Power and Data, along with Bridge, Ready, Signal, Clip, Thermal and Fault for each channel, provide accurate diagnos- tics.

Blue Power Indicator flashes if the ampli- fier shuts off due to an under-/over-voltage condition on the AC mains.

Advanced protection circuitry guards against: shorted outputs, open circuits, DC, mismatched loads, general overheat- ing, under-/over-voltage, high-frequency overloads and internal faults.

Proven Crown AB+B Multi-Mode®output topology.

Continuously-variable-speed fans opti- mize cooling efficiency.

Three Year, No-Fault, Fully-Transferable Warranty completely protects your invest- ment and guarantees its specifications.

2 How to Use This Manual

This manual provides you with the necessary information to safely and correctly setup and operate your amplifier. It does not cover every aspect of installation, setup or operation that might occur under every condition. For addi- tional information, please consult Crown’s Amplifier Application Guide (available online at www.crownaudio.com), Crown Tech Support, your system installer or retailer.

We strongly recommend you read all instruc- tions, warnings and cautions contained in this manual. Also, for your protection, please send in your warranty registration card today, or reg- ister online at www.crownaudio.com. And save your bill of sale—it’s your official proof of pur- chase.

page 5

Image 5
Contents Some models may be exported under the name Amcron CTsOr has been dropped Important Safety InstructionsCTs Series amplifiers require Class 2 output wiring European Representatives Name and Address Safety StandardFamily Name CTs EMC StandardsTroubleshooting SetupSpecifications AC Power Draw and Thermal DissipationFeatures How to Use This ManualWelcome Proven Crown AB+B Multi-Modeoutput topologyUnpack Your Amplifier Install Your Amplifier SetupChoose Output Wire and Connectors Choose Input Wire and ConnectorsCrown recommends using professionally constructed, high Over 60 ft 18.3 mDual 70V Mode Wire Your System Dual 8/4 ModeBridge-Mono 100V Mode Bridge-Mono 16/8 ModeConnect to AC Mains Startup ProcedureOperation PrecautionsReady Indicator Front Panel Controls Indicators Bridge Mode IndicatorSignal Indicator Clip IndicatorOutput Connectors Back Panel Controls Connectors AC Power Cord ConnectorAccessory Panel Input ConnectorsAdvanced Features Options Attenuation in dB Channel Level ControlWall-Mount level control panels for use with VCA module Options Control ModulesChoosing the Right Module Input SensitivityThermal Level Control TLC is active TroubleshootingRefer to .1.6 for specific voltage requirements Mode switch was switched while the power was on Power supply thermal overloadDual Mode SpecificationsCommon Mode Rejection CMR 20 Hz to 1 kHz Crosstalk below rated power, 20 Hz to 1 kHzPower Draw at Idle 120VAC mains, all channels in 70V mode Dimensions Width, Height, DepthCTs 8200 Typical Frequency Response 1 W CTs 8200 Typical Output Impedance vs. Frequency AC Power Draw and Thermal Dissipation AC Power Draw Thermal DissipationOhms Bridge 320x4 Service 12/01 WarrantyWorldwide Except USA & Canada CTs Multi-Channel Power Amplifiers Nature of Problem Crown Factory Service InformationThis page Intentionally Left Blank CTs Multi-Channel Power Amplifiers