CTs
3Setup
3.6.3Bridge-Mono 16/8 Mode
CAUTION: Never change the position of the Mode Switch while the amplifier power is on. See Section 5.2.2 for more information.
Typical input and output wiring, along with level control and Mode Switch settings are shown in Figure 3.8. Make sure the Mode switch is set to the “Bridge 16/8” position.
INPUTS: Connect input wiring only to the lower-
OUTPUTS: Connect the speaker across the posi- tive terminals of each channel pair. Do not use the negative terminals of the channel pair when the pair is being operated in
BRIDGE |
|
DUAL | DUAL |
CH 2 | CH 1 |
Output panel |
|
shown with |
|
| |
cover plate |
|
removed. |
|
CH 4 | CH 3 |
DUAL | DUAL |
BRIDGE |
|
See the Crown Amplifier Appli- cation Guide, available online at www.crownaudio.com, for pin assignments for commonly used connector types.
NOTE: When operating the channel pair in
3.6.4 Bridge-Mono 100V Mode
CAUTION: Never change the position of the Mode Switch while the amplifier power is on. See Section 5.2.2 for more information.
Typical input and output wiring, along with level control and Mode Switch settings are shown in Figure 3.9. Make sure the Mode switch is set to the “Bridge 100V” position.
INPUTS: Connect input wiring only to the lower-
OUTPUTS: Connect the speaker across the posi- tive terminals of each channel pair. Do not use the negative terminals of the channel pair when the pair is being operated in
NOTE: When operating the channel pair in
Figure 3.8 System Wiring and Control Settings, Bridge-Mono Mode, 16/8 Ohm.
100V |
|
|
| BRIDGE |
|
| DUAL | DUAL |
| CH 2 | CH 1 |
Output panel |
|
|
shown with |
|
|
|
| |
cover plate |
|
|
removed. | CH 4 | CH 3 |
| ||
| DUAL | DUAL |
| BRIDGE |
|
Figure 3.9 System Wiring and Control Settings, Bridge-Mono Mode, 100V