8.Test the system to ensure that the MLC is functioning properly.

9.Mount the MLC.

Before mounting the MLC to a wall or furniture, make sure that all device cables are connected to the MLC rear panel. Disconnect power at the source from all devices in the system.

a.Align the MLC wall frame to the metal mounting bracket, which you attached to the mounting surface in step 3.

b.Holding the wall frame in place on the bracket, press the MLC into the frame until the two tabs on either side of the unit snap into the opening of the metal bracket, holding the MLC in place.

Mounting the MLC 62 EU in a Raceway

Electrical Junction Box

Metal Bracket

Wall Frame

Y

DISPLA

OFF

ON

VOLUME

VIDEO

PC

MUTE

LAPTOP

Using a Spacer (Optional)

MLC 62 RS EU

If you are experiencing difficulty with the MLC staying in place when installed in a cable raceway, this may be due to a gap between the metal mounting bracket and the wall frame.

When this gap exists, the tabs on the sides of the MLC do not reach the metal mounting bracket and the MLC does not snap completely into the metal bracket.

You can remedy this situation by installing a spacer (provided with the MLC) between the metal mounting bracket and the rim of the junction box. This spacer appears very similar to the metal mounting bracket, except that it has holes instead of slots for the mounting screws, is engraved with the words “Optional Spacer” and “Place behind bracket,” and has a slightly larger center opening than the metal mounting bracket.

1.Mount the electrical box in the raceway.

2.Attach the spacer to the electrical box by inserting two of the included screws in the holes at the sides of the spacer. Leave the screw heads protruding approximately 1/8 inch from the surface of the spacer.

3.With the “Front” label facing toward you, place the metal mounting bracket onto the spacer so that the screw heads pass through two of the slotted holes in opposite sides of the bracket.

NOTE: Ensure that the surface of the mounting

 

bracket containing the word “Front” is

 

facing out (away from the spacer and

Junction Box

junction box).

 

4.Rotate the mounting bracket as necessary to ensure that the MLC will be positioned straight on the mounting surface and not skewed to either side.

5. Tighten the screws to secure the bracket to the spacer.

6.Pull the cables through the electrical box and the wall

frame.

7. Disconnect power from all devices at the source and connect all cables to the MLC.

8.Align the wall frame with the metal mounting bracket on the mounting surface.

9.Press the MLC into the wall frame until the unit snaps

into place.

Cable Raceway

 

Raceway

Junction Box

Mounting Bracket

Spacer

Metal Spacer

Metal Bracket

Wall Frame

MLC 62 RS EU

Y

 

DISPLA

OF

F

 

 

ON

 

VOLUME

 

O

 

VIDE

PC

MUTE

 

LAPTOP

 

Extron Headquarters

 

Extron Europe

Extron Asia

Extron Japan

Extron China

Extron Middle East

Extron Korea

Extron India

+1.800.633.9876 (Inside USA/Canada Only)

+800.3987.6673

+800.7339.8766

+81.3.3511.7655

+4000.398766

+971.4.2991800

+82.2.3444.1571

1800.3070.3777

Extron USA - West

Extron USA - East

(Inside Europe Only)

(Inside Asia Only)

+81.3.3511.7656 FAX

Inside China Only

+971.4.2991880 FAX

+82.2.3444.1575 FAX

Inside India Only

+1.714.491.1500

+1.919.863.1794

+31.33.453.4040

+65.6383.4400

 

+86.21.3760.1568

 

 

+91.80.3055.3777

+1.714.491.1517 FAX

+1.919.863.1797 FAX

+31.33.453.4050 FAX

+65.6383.4664 FAX

 

+86.21.3760.1566 FAX

 

 

+91.80.3055.3737 FAX

 

 

 

 

 

 

 

 

 

4

© 2012 Extron Electronics —­ All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com

68-2166-51 Rev. A

 

03 12

Image 4
Contents MLC 60 Series Setup Guide Installation StepsPrepare the installation site Optional Change the faceplate and buttons as neededAttach the metal mounting bracket to the junction box MLC 62 EU and MLC 62 MK Setup GuideConnect the cables to the MLC rear panel ports USB Connect and apply powerUSB a Using a Spacer Optional Mounting the MLC 62 EU in a RacewayMount the MLC MLC 62 RS EU

MLC 62 RS MK, MLC 62 RS EU specifications

The Extron MLC 62 RS MK and MLC 62 RS EU are sophisticated control systems designed for managing audiovisual (AV) equipment in various environments such as classrooms, lecture halls, and conference rooms. These models are part of Extron's well-established MediaLink Controller series, known for their user-friendly interfaces and powerful functionality. They are critical tools for simplifying AV operation and creating an intuitive experience for users.

One of the standout features of the MLC 62 RS MK and MLC 62 RS EU is their ability to control multiple AV devices from a single interface. This includes projectors, displays, video conferencing systems, and audio equipment. By consolidating control into one device, users can save time and reduce the complexity of managing AV installations.

The controllers are equipped with six customizable buttons that can be programmed to perform a variety of functions, such as turning equipment on or off, switching input sources, or adjusting volume levels. This versatility means that users can tailor the system to meet their specific needs effectively, ensuring a seamless AV experience.

Incorporating advanced technologies, the MLC 62 RS models feature Extron's robust RS-232 and relay control capabilities, allowing for direct communication with a wide range of third-party AV devices. These features facilitate integration in diverse installations and ensure compatibility with various components, minimizing issues related to devices not communicating properly.

The design of the MLC 62 RS MK and MLC 62 RS EU is also user-centric. With an intuitive graphical user interface and easy-to-read labels, operators can easily navigate the system without needing extensive technical knowledge. This design philosophy enhances usability in educational and professional settings, where quick access to AV control is essential.

Moreover, both models support Ethernet control, enabling remote management and monitoring of AV systems from a centralized location. This feature makes it easier for IT and AV professionals to troubleshoot issues, perform updates, and ensure optimal performance of the AV ecosystem.

Another important characteristic is their compact form factor. These controllers can be easily mounted on a wall or installed in a tabletop configuration, making them suitable for various applications where space efficiency is a priority.

Overall, the Extron MLC 62 RS MK and MLC 62 RS EU are powerful and flexible control solutions designed to meet the demands of modern AV environments. With their intuitive controls, extensive connectivity options, and ease of integration, they stand out as essential tools for enhancing AV management and user experience in a multitude of settings.