Emerson 5081T-FF/FI instruction sheet 140 125, 125 650 ±.015, Csa

Page 17

This document contains information proprietary to Rosemount Analytical, and is not to be made available to those who may compete with Rosemount Analytical.

4X R .25

2X FULL R

.140

Ø .125

ROSEMOUNTRANALYTICAL

MODEL

SA R LR34186

5081-T-FI-69

ENCLOSURE 4

Exia ENTITY

INTRINSICALLY SAFE FOR

CLASS I, GRPS A, B, C & D

CLASS II, GRPS E, F & G

CLASS III

T3A Tamb = 70°C

HAZARDOUS AREA WHEN CONNECTED

PER DWG. 1400285

WARNING: COMPONENT SUBSTITUTION

MAY IMPAIR INTRINSIC SAFETY.

CLASS I, DIV. 2, GRPS A,B,C & D SUITABLE FOR

CLASS II, DIV. 2, GRPS E, F & G

T3A Tamb= 70°C

WARNING-EXPLOSION HAZARD-DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS AREA IS KNOWN TO BE NON- HAZARDOUS.

WARNING-EXPLOSION HAZARD-SUBSTITU- TION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIV 2.

CLASS I, GRPS B,C & D

CLASS II, GRPS E, F & G

CLASS III

Tamb = 65°C MAX

Tamb ABOVE 60°C USE 75°C MINIMUM

RATED WIRING

SEAL REQUIRED TO BE INSTALLED

WITHIN 50 mm OF THE ENCLOSURE.

KEEP COVER TIGHT WHILE CIRCUITS

ARE LIVE.

9241516-01/A

.125

.650 ±.015

RELEASE DATE

ECO NO

REV

 

 

REVISIONS

 

 

 

LTR

ECO

DESCRIPTION

5-6-04

8925

A

.120 ±.015

2.56 ±.02

2.180 ±.005

BY DATE CHK

THIS DOCUMENT IS

CERTIFIED BY

CSA

REV A

 

REV

 

REV

 

REV

 

REV

 

REV

REVISIONS NOT PERMITTED

B 9241516-01

1.30 ±.02

W/O AGENCY APPROVAL

4 FINISH:SILKSCREEN BLACK EPOXY PAINT (BAKED).

3.ARTWORK IS SHEET 2 OF 2.

2.NO CHANGE WITHOUT CSA APPROVAL.

1MATERIAL: AISI 300 SERIES STAINLESS STEEL .015+/-.005 THICK. MATERIAL TO BE ANNEALED & PASSIVATED. MAXIMUM HARDNESS BRINELL 190.

NOTES: UNLESS OTHERWISE SPECIFIED

UNLESS OTHERWISE SPECIFIED

.XX

+

TOLERANCES

 

 

.030

+

1/2

.XXX

-

ANGLES

+

.010

-

 

 

-

 

 

DIMENSIONS ARE IN INCHES

REMOVE BURRS & SHARP EDGES .020 MAX

MACHINED FILLET RADII .020 MAX

NOMINAL SURFACE FINISH 125

MATERIAL

1

FINISH

4

ITEM

PART NO

 

 

DESCRIPTION

QTY

 

 

 

BILL OF MATERIAL

 

 

APPROVALS

DATE

Uniloc

 

Rosemount Analytical,

 

 

 

 

Irvine, CA 92606

 

 

 

 

 

 

Uniloc Division

 

 

 

 

 

 

2400 Barranca Pkwy

DRAWN

B. JOHNSON

5/3/04

TITLE

 

 

 

CHECKED

J. FLOCK

 

 

LABEL, I.S. CSA

5/6/04

 

 

PROJECT

J. FLOCK

5/6/04

 

 

5081-T-FI

 

ENGR APVD

 

DWG NO

REV

THIS DWG CREATED IN

 

SIZE

9241516-01

SOLID EDGE

 

 

 

A

 

 

B

 

 

 

 

 

 

SCALE 2:1

 

SHEET 1 OF 2

17

Image 17
Contents Read this page Before Proceeding Essential InstructionsTransmitter Specifications @ 25C Physical SpecificationsLoop Specifications Recommended SensorsI T N E X T Infrared Remote Controller FigureProcess Display 25.0C 12.00mADiagnose Menu Program MenuCalibrate Menu Wiring Model 5081T-FF/FI WiringPower Wiring Wiring Through a Junction BOXInstallation InstallationUnpacking and Inspection Rotating the DisplayPage Page Page Page Page Model 2X Full RFM REV a Finishsilkscreen Black Epoxy Paint Baked1400298 a Wiring1400298 Label1400284 1400284Hazardous Classified Locations NON-HAZARDOUS LocationsCSA 140 125125 650 ±.015 Hazardous Area 14002851400285 Unclassified Area125 4X R II 1 G 1180Baseefa REV a Artwork is Sheet 2 No Change Without Baseefa ApprovalFisco Transmitter Maintenance MaintenanceOverview Exploded View of Model 5081-T-FF/FI TransmitterDescription QUICK-START Engineering SpecificationsTo reset transmiter to factory default settings Specifications subject to change without notice