Emerson 5081T-FF/FI 2X Full R, Model, FM REV a, Finishsilkscreen Black Epoxy Paint Baked

Page 14

14

This document contains information proprietary to Rosemount Analytical, and is not to be made available to those who may compete with Rosemount Analytical.

4X R .25

2X FULL R

.140 ±.005

Ø .125

ROSEMOUNTRANALYTICAL

MODEL

FM

5081-T-FI-67

APPROVED

INTRINSICALLY SAFE FOR CLASS I, II & III, DIV. 1, GRPS. A,B,C,D,E,F & G HAZARDOUS AREA WHEN

CONNECTED PER DWG. 1400284

T4 Tamb= 70°C

NON-INCENDIVE

CLASS I, DIV. 2, GRPS. A,B,C & D DUST IGNITION PROOF CLASS II AND III, DIV. 1, GRPS. E, F & G

WARNING: COMPONENT SUBSTITUTION MAY IMPAIR INTRINSIC SAFETY OR SUITABILITY FOR DIV.2.

NEMA 4X ENCLOSURE.

EXPLOSION PROOF

CLASS I, DIV.1, GRPS. B,C & D

CLASS II, DIV. 1, GRPS. E,F & G

CLASS III, DIV. 1

PER DWG. 1400298

9241515-01/A

RELEASE DATE

ECO NO

REV

 

 

REVISIONS

5-6-04

8933

A

LTR

ECO

DESCRIPTION

.120 ±.015

2.56 ±.02

2.180 ±.005

BY DATE CHK

THIS DOCUMENT IS

CERTIFIED BY

FM REV A

REV

REV

REV

B 9241515-01

.125

.650 ±.015

1.30 ±.02

4 FINISH:SILKSCREEN BLACK EPOXY PAINT (BAKED).

REV

REV

REVISIONS NOT PERMITTED

W/O AGENCY APPROVAL

3.ARTWORK IS SHEET 2 OF 2.

2.NO CHANGE WITHOUT FM APPROVAL.

1MATERIAL: AISI 300 SERIES STAINLESS STEEL .015+/-.005 THICK. MATERIAL TO BE ANNEALED & PASSIVATED. MAXIMUM HARDNESS BRINELL 190.

NOTES: UNLESS OTHERWISE SPECIFIED

UNLESS OTHERWISE SPECIFIED

.XX

+

TOLERANCES

 

 

.030

+

1/2

.XXX

-

ANGLES

+

.010

-

 

 

-

 

 

DIMENSIONS ARE IN INCHES

REMOVE BURRS & SHARP EDGES .020 MAX

MACHINED FILLET RADII .020 MAX

NOMINAL SURFACE FINISH 125

MATERIAL

1

FINISH

4

ITEM

PART NO

 

 

DESCRIPTION

QTY

 

 

 

BILL OF MATERIAL

 

 

APPROVALS

DATE

Uniloc

Rosemount Analytical,

 

 

 

Irvine, CA 92606

 

 

 

 

 

 

Uniloc Division

 

 

 

 

 

 

2400 Barranca Pkwy

DRAWN

B. JOHNSON

5/3/04

TITLE

 

 

 

CHECKED

J. FLOCK

5/6/04

 

LABEL, I.S. FM

 

 

 

 

PROJECT

J. FLOCK

5/6/04

 

 

5081-T-FI

 

ENGR APVD

 

DWG NO

REV

THIS DWG CREATED IN

 

SIZE

9241515-01

SOLID EDGE

 

 

 

A

 

 

B

 

 

 

 

 

 

SCALE 2:1

SHEET 1 OF

2

Image 14 Contents
Essential Instructions Read this page Before ProceedingLoop Specifications Physical SpecificationsTransmitter Specifications @ 25C Recommended SensorsInfrared Remote Controller Figure I T N E X T25.0C 12.00mA Process DisplayDiagnose Menu Program MenuCalibrate Menu Wiring Wiring Model 5081T-FF/FIWiring Through a Junction BOX Power WiringUnpacking and Inspection InstallationInstallation Rotating the DisplayPage Page Page Page Page FM REV a 2X Full RModel Finishsilkscreen Black Epoxy Paint Baked1400298 Wiring1400298 a LabelHazardous Classified Locations 14002841400284 NON-HAZARDOUS LocationsCSA 140 125125 650 ±.015 1400285 1400285Hazardous Area Unclassified AreaBaseefa REV a II 1 G 1180125 4X R Artwork is Sheet 2 No Change Without Baseefa ApprovalFisco Overview MaintenanceTransmitter Maintenance Exploded View of Model 5081-T-FF/FI TransmitterDescription QUICK-START Engineering SpecificationsTo reset transmiter to factory default settings Specifications subject to change without notice
Related manuals
Manual 24 pages 36.88 Kb