6. Remote Control Pass-through mode
When PC sets the LCD monitor to Remote Control Pass through mode, the LCD shall send a three bytes packet (followed by “CR”) in response to RCU button activation. Note, that in this mode the RCU shall have no effect on the monitor function. For example: “+Volume” will not change the volume in the LCD but only sends “+Volume” code to PC over the RS232 port.
RCU Pass-through Command description:
Length | Total Byte of Message excluding “CR” |
|
|
TV ID | Identification for each of TV |
|
|
Command Type | Identify command type, |
| “p” (0x70h) : RCU |
|
|
Value[1~2] | Two bytes ASCII that defines the value |
|
|
CR | 0x0D |
|
|
RCU Pass-through Command Format:
Reply: (Command Type= “p”)
Name | Length | ID | Command | Value1 | Value2 | CR |
|
|
| Type |
|
|
|
|
|
|
|
|
|
|
Byte Count | 1 Byte | 2 Byte | 1 Byte | 1 Byte | 1 Byte | 1 Byte |
|
|
|
|
|
|
|
Bytes order | 1 | 2~3 | 4 | 5 | 6 | 7 |
|
|
|
|
|
|
|
Example1: User press “Menu” Key form RCU to
Reply (Hex Format)
Name | Length | ID | Command | Value1 | Value2 | CR |
|
|
| Type |
|
|
|
|
|
|
|
|
|
|
Hex | 0x36 | 0x30 | 0x70 | 0x31 | 0x41 | 0x0D |
|
| 0x33 |
|
|
|
|
|
|
|
|
|
|
|
Example2: User press “5” Key form RCU to
Reply (Hex Format)
Name | Length | ID | Command | Value1 | Value2 | CR |
|
|
| Type |
|
|
|
|
|
|
|
|
|
|
Hex | 0x36 | 0x30 | 0x70 | 0x30 | 0x35 | 0x0D |
|
| 0x36 |
|
|
|
|
|
|
|
|
|
|
|