Sanyo STK-RCS-7TWSUA service manual How to Test Run the Air Conditioner

Page 23

How to Test Run the Air Conditioner

After turning on the power of the air conditioner, use the remote controller and follow the steps below to conduct the test run.

(1) Set the remote controller in Test Run mode. (Fig. 9)

a)Press and hold the NIGHT SETBACK button and the 1HR. TIMER button.

b)Then press and hold the ACL (Reset) button with a pointed object such as the tip of a pen. After 5 seconds, release the ACL button first.

c)Then release the NIGHT SETBACK and 1HR. TIMER buttons.

d) appears and “oP-1” blinking in the remote controller clock display area. (Fig. 10)

(2)Start Cooling mode test run by pressing the ON/OFF operation button of the remote controller. (Fig. 9)

This starts the fan producing uncooled forced air with the 3 indicator lamps (OPERATION lamp, TIMER lamp, and HIGH POWER lamp) on the main unit blinking. (Fig. 11)

After 3 minutes, the system shifts into cooling operation, and cool air will start to be felt. Cooling mode test run is unaffected by the room tempera- ture.

(3)Press the ON/OFF operation button of the remote controller again to stop the test run. (Fig. 9)

(4)Finally press the ACL (Reset) button of the remote controller to release it from Test Run mode to return to normal mode. (Fig. 9)

” and “oP-1” will disappear from the remote controller clock display area.

NOTE

Troubleshooting:

In the event that the green OPERATION lamp is blink- ing upon powering up the system, an error condition exists. In this case, refer to the self-diagnostics proce- dure which can be seen by opening the air-intake grille.

IMPORTANT

After the test run is completed, be sure to press the ACL (Reset) button to return to normal mode. The air conditioner will not operate correctly if this is not done.

ON/OFF

operation button

NIGHT SETBACK button

1 HR.TIMER button

ACL (Reset)

SENSOR button

button

 

 

Fig. 9

Fig. 10

OPERATION button

OPERATION lamp

TIMER lamp

HIGH POWER lamp

REMOTE CONTROL receiver

Fig. 11

4

Image 23
Contents Product Code No 852 353 Model NoPlease Read Before Starting Table of Contents Specifications Type Indoor Unit Model No Ceiling Cassette TypeWall Mounted Type SELF-DIAGNOSTICS Operation lamp Timer lamp High Power lamp Remote Control receiverCode Diagnostics items Operation buttonSelf-Diagnostics Table Wall Mounted Type OI-852-6-4181-139-00-0 STK-RCS-7TWSUA Mode D’EMPLOISafety Instructions ContentsAlert Symbols Installation LocationSymbols FeaturesRemote Control Unit Display Remote Control Unit ON/OFF operation button Mode selector buttonHR. Timer button 1-HOUR OFF Timer Timer Select buttonAutomatic Operation Only for COOL/DRY/HEAT Model Operation with the Remote Control UnitAutomatic fan speed Cooling and DRY ModeHeating Mode Only for COOL/DRY/HEAT Model Special RemarksSetting the Timer Adjusting the Airflow Direction Using the 1-HOUR OFF TimerAppendix B Installation Instructions STK-RCS-7TWSUA Sanyo Canada Inc Installation locationSwitching the room temperature sensor Sanyo Commercial SolutionsInstalling directly onto the wall Installing with in-wall junction boxHow to wire the remote controller How to Test Run the Air Conditioner Appendix C 7000 BTU, 9000 BTU, and 12000 BTU inverter models Parts included in the packageRefer to the Installation Instructions BTU and 24000 BTU inverter models Operation lamp Timer lamp Quiet lamp ION lamp