Sanyo STK-RCS-7TWSUA service manual BTU and 24000 BTU inverter models

Page 27

B. 18000 BTU and 24000 BTU inverter models

(1)Remove the air intake grille.

(2)Remove the terminal cover. Pull out the thermistor, then remove the grille.

For details on steps (1) and (2), refer to the Installation Instructions included in the outdoor unit package.

(3)Disengage the top cover from the tabs on the sides of the component box, then pull the cover toward you to remove it. (Fig. 1)

(To disengage the tabs, pull the sides of the top cover sideways and outward from the component box.)

(4)Disconnect the indicator-side connector (10P) of the wires that connect the indi- cator and component box (Fig. 2a). Then disconnect the connector on the com- ponent box side (10P) and remove the wires. (Lifting the P.C. board up slightly will make this work easier.) (Fig. 2b)

(5)After removing the wires, insert Connector 1 of the wires (Fig. 3a) that were included in the kit package into the indicator (Fig. 2a), then insert Connector 2 into the component box. (Fig. 2b)

At this time, pass the wires through so that they are held inside the 2 holders on the sides of the component box. (Fig. 3b)

(6)Feed the wire harness that was included in the wired remote controller package into the right lower rear of the unit. (Fig. 4a)

Be careful not to damage the wire harness when installing the conduit during unit installation work.

(7)Pass the wire harness through the wire tube that was included in the kit package. Then connect Connector 3 (Fig. 3a) to the wire harness connector (4P). (Fig. 4c)

(8)Take the wires (Fig. 3a) and use a wire clamp to bind together the wire for the noise filter and the wire for the thermistor (Fig. 5a). Then position them so that the noise filter is contained within the space of the component box. (Fig. 5b)

(9)Pass the wire tube through the clamping strap, and temporarily fasten in place with the screw. Next, use a clamp and bind the wires together immediately above the clamping strap, and fasten in place with the screw in order to prevent pulling on the wire harness. (Fig. 6a)

Install the wire tube so that the wires cannot be damaged by the edge of the metal plate. (Fig. 6a)

When re-installing the grille, confirm that there is no slack in the wire harness wires.

(10)Install the top cover on the component box. (Fig. 8)

(11)Route the wire harness out through the small cut-out located at the bottom right side of the indoor unit frame. (Fig. 7a)

(12)Apply the label that was included in the package at a location close to the self- diagnostic label applied to the air intake grille. (Fig. 7b)

(13)Refer to the Installation Instructions that were included in the outdoor unit pack- age and re-install the grille, thermistor, terminal cover, and air intake grille.

<Completion drawing >

Fig. 8

3

Image 27
Contents Product Code No 852 353 Model NoPlease Read Before Starting Table of Contents Specifications Ceiling Cassette Type Wall Mounted TypeType Indoor Unit Model No SELF-DIAGNOSTICS Operation lamp Timer lamp High Power lamp Remote Control receiverCode Diagnostics items Operation buttonSelf-Diagnostics Table Wall Mounted Type OI-852-6-4181-139-00-0 STK-RCS-7TWSUA Mode D’EMPLOISafety Instructions ContentsAlert Symbols Installation LocationFeatures Remote Control Unit DisplaySymbols Remote Control Unit ON/OFF operation button Mode selector buttonHR. Timer button 1-HOUR OFF Timer Timer Select buttonAutomatic Operation Only for COOL/DRY/HEAT Model Operation with the Remote Control UnitAutomatic fan speed Cooling and DRY ModeHeating Mode Only for COOL/DRY/HEAT Model Special RemarksSetting the Timer Adjusting the Airflow Direction Using the 1-HOUR OFF TimerAppendix B Installation Instructions STK-RCS-7TWSUA Sanyo Canada Inc Installation locationSwitching the room temperature sensor Sanyo Commercial SolutionsInstalling directly onto the wall Installing with in-wall junction boxHow to wire the remote controller How to Test Run the Air Conditioner Appendix C 7000 BTU, 9000 BTU, and 12000 BTU inverter models Parts included in the packageRefer to the Installation Instructions BTU and 24000 BTU inverter models Operation lamp Timer lamp Quiet lamp ION lamp