SPECIFICATIONS

Television system

NTSC/PAL color signal standard (Switchable)

 

 

Picture resolution

NTSC:

720 x 480 (Super+/Super/High), 352 x 480 (Standard)

 

 

PAL:

720 x 576 (Super+/Super/High), 352 x 576 (Standard)

 

 

 

 

Compression

MPEG2 (Video), MPEG1 Layer2 (Audio)

 

 

Picture quality

4 levels (Super+/Super/High/Standard)

 

 

Recording type

Frame

 

 

 

Recording speed

1 (NTSC: 30 fps or PAL: 25 fps)

 

 

Recording area

1

 

 

 

Playback

Playback/Still/Search/Cue/Review/Frame advance/Slow

 

 

mode

Time/date search

Search by time and date

 

 

 

Search

 

 

 

 

 

Alarm search

Search by alarm event list

 

 

 

 

 

 

 

 

Menu language

English/French/German/Spanish

 

Clock settings

Day/Month/Year/Hours/Minutes/Seconds

 

 

Video input terminal

1.0 V (p-p) / 75 unbalanced (BNC)

 

 

Video output terminal

1.0 V (p-p) / 75 unbalanced (BNC)

 

 

Audio input terminal

-8 dbs, 27 kunbalanced (RCA pin jack)

 

 

 

Audio output terminal

-8 dbs, 600 unbalanced (RCA pin jack)

 

OTHER

Microphone input terminal

-60 dbs, 10 kunbalanced (φ 3.5 mm mini jack)

 

LAN terminal

100BASE-TX/10BASE-T (RJ-45)

 

 

USB terminal

For CompactFlash card reader and CD-R/RW drive (Front)

 

 

 

RS-485 terminal

3 terminals (A, B, GND)

 

 

lock)

Remote control input

External switch connection or VA-RMN01 remote control

 

terminal

 

 

 

 

 

 

 

 

 

 

(Push

Clock adjust input terminal

Normal open, Low level active

 

 

Clock adjust output terminal

Normal 5 V, Low level active

 

 

 

connector

Series REC input terminal

Normal open, Low level active

 

 

Alarm input terminal

Normal open, Low level active

 

 

Non REC output terminal/

Normal 5 V, Low level active

 

 

Series REC output terminal

 

 

 

 

 

 

Control

 

 

 

 

 

Alarm reset input terminal

Normal open, Low level active

 

 

 

 

Alarm output terminal

Normal 5 V, Low level active

 

 

 

Warning output terminal

Open collector (500 mA), Low level active

 

 

 

Full out warning terminal

Open collector (50 mA), Low level active

 

 

Power

120 V to 240 V AC, 50/60 Hz

 

Current consumption

440 mA

 

 

 

Operating environment

Temperature: 5°C to 40°C, Humidity: 10 % to 80 %

 

 

Dimensions

210 (W) x 96 (H) x 380 (D) mm

 

 

Weight

3.6 kg (3 kg without a HDD)

 

 

Note that product appearance and specifications are subject to change without prior notice.

50

English

Image 51
Contents Page Avoiding Electrical Shock and Fire PrecautionService LocationIntroduction Power cord Ferrite corePower cord tie Application software For LAN connection cable/ DVR power cordContents Other Contents SettingsInstallation conditions Before USEHard disk and cooling fan are consumables Care Backup batteryFor important recordings Hard disk protectionFront panel Names and Functions of PartsCord tie Power cord holderALL Reset switch Rear panelSystem controller connections Installation and ConnectionsConnecting a remote control circuit Basic connectionsConnecting cables to the control and alarm terminals Connecting to a networkConnecting the power cord Example Normal screen Screen Display and PositionOperation display area Changing the position of the operating displayPress the Menu button Setting the LANGUAGE/CLOCKWhen you have made a selection, press Button To change the languagePress the or button to select Press the button Setting the LANGUAGE/CLOCKSetting the time Example Setting 20 May, 2004, 830 AMNormal RECORDING/TIMER Recording Timer recordingNormal recording When alarm input is detected Alarm RecordingAlarm recording Set alarm recordingPlayback while fast-forwarding/rewinding PlaybackPress the Still button Viewing still imagesFrame advance reverse During playback, press the Still buttonImage to search Search in Search screen Alarm searchCheck that Alarm Search is Selected, and press the button Searching for Recorded ImagesPress the or button to select the image to play back Enter the desired alarm numberYou can also search by specifying the desired alarm number Date/time searchIf no image exists for the specified time Searching for Recorded ImagesPress the button, and set the date/time to search Press the button to select View Then press the buttonPreview Copying imagePress the and buttons to select Copy START, and then press Copying to CF Cards or CD-R/RW Discs and FormattingFormatting a CompactFlash card or CD-RWReleasing the key lock function Setting the key lock functionPress the or button to select the desired menu Menu Configuration and OperationsTo restore menu setting items to their initial values Displaying the menu screen and sub- menu screensMenu Configuration and Operations Overview of sub-menusHDD SET JP.46 USE flashes Summer Time SET settingsPress the or button to change the setting Select 1. LANGUAGE/CLOCK SET Press the buttonEXT.CLOCK SET settings When USE is selected for Mode under1st DVR 2nd DVR Switch DVR DVR DVR DVR REC Mode SET setting items REC Mode SETPress the or button to select YES, then press the button SettingsStarting recording again when Full indicator lights Select 2. REC Mode SET, and press ButtonPress the button once Timer REC SETTimer setting items Select 3. Timer REC SET, and press ButtonPress the button to move the cursor to the next item Timer REC SETTo cancel all timer reservations Timer reservations spanning more than 24 hoursSetting holidays DISPLAY/BUZZER SET DISPLAY/BUZZER SET setting itemsPress the and buttons to change the setting, then press Select 4. DISPLAY/BUZZER SET, Press the buttonDISPLAY/BUZZER SET screen appears Security Lock SET Password setting examplePassword setting Setting passwordsSecurity Lock SET Setting the user passwordLights, and the security lock is set Admin or UserPress the and buttons to move Cursor to REC ControlSelect 6.RS-485/NETWORK/REMOTE SET and press the button Network connections and settingsSettings for PC or network connection RS-485/NETWORK SETSelect 6. RS-485/NETWORK/REMOTE SET, and press the button RS-485 connections and settingsDisable flashes Setting Remote SETPower LOSS/USED Time Select 7. Power LOSS/USED Time Press the buttonDisplays the total amount of disk 1 operation time Menu button Button button Menu UPLOAD/DOWNLOADOperations Select 8. Menu Upload DOWNLOAD, and press the buttonNo flashes „ If Mirroring setting is loadedPress the and buttons to select YES and press the button To save menu items to CompactFlash cardTo exit Formatting CompactFlash cardsHDD SET Initializing the hard diskSelect 9. HDD SET, and press Button Setting conditions Hard disk setting screenAdding a hard disk RS-485 termination switch settings RS-485 specificationsDVR/VCR command table PAL SpecificationsUnit mm 210 Front 391.5 Side DimensionsIndex Index Timer button Timer indicatorTimer recording TV System selector switch UP button