Extension of a point to point FD (Full Duplex) Fast Ethernet connection:

Problem:

The distance between two FD stations running on UTP needs to be extended.

UTP

Up to 100m

FD Fast Ethernet Station

FD Fast Ethernet Station

Figure 1-10 Point-to-Point Full Duplex Connection

Solution:

Using two AMC-101s with AMC-M/100BT/R modules can extend the range up to tens of kilometers.

 

 

 

UTP

 

FD Fiber Optic Link

 

 

 

UTP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Up to 80m

 

 

 

 

 

 

 

Up to 80m

 

 

 

 

Up to tens of kms

 

 

 

 

 

 

 

 

 

 

 

 

FD Fast Ethernet Station

 

AMC-101 with

FD Fast Ethernet Station

AMC-101 with

 

 

 

 

 

AMC-M/100BT/R Module

 

AMC-M/100BT/R Module

Figure 1-11 Extending Point-to-Point Full Duplex Connection

1-8 Fast Ethernet Applications

Image 18
Contents AMC-101 Page Warranty Safety Warnings Regulatory Information Declaration of Conformity Contents Operation List of Figures List of Tables General Retimed Modules TransparentFeatures STP UTPGeneral Applications Dissimilar Device ConnectivityWrap Dual Single Mode SM to Multimode MM Conversion Fddi and Fast Ethernet Operations Problem Fast Ethernet ApplicationsRepeater Half Duplex Connection over UTP 10 Point-to-Point Full Duplex Connection 12 Full Duplex Connection over UTP Specifications Optical Module Characteristics 0.25 dB/Km for 1550 nm modules Electrical Module Characteristics Introduction Specifications Unpacking Site RequirementsInstallation of a Installation Two UnitsAC Power Connection Cable ConnectionsGrounding AMC-101 Modules MM/SC/13/R ModuleMM/SC/13/T Module MM/SC/13/T Module Front PanelMM/ST/13/R Module MM/ST/13/R Module Front PanelMM/ST/13/T Module MM/ST/13/T Module Front PanelSM/ST/13/R Module 10 SM/ST/13/R Module Front PanelSM/ST/13/T Module 11 SM/ST/13/T Module Front PanelSM/FC/13/T Module 12 SM/FC/13/T Module Front PanelSM/ST/13L/R Module 13 SM/ST/13L/R Module Front PanelSM/ST/13L/T Module 14 SM/ST/13L/T Module Front PanelSM/SC/13L/R Module 15 SM/SC/13L/R Module Front PanelSM/ST/13LH/R Module 16 SM/ST/13LH/R Module Front PanelSM/FC/13LH/R Module 17 SM/FC/13LH/R Module Front PanelSM/ST/15L/R Module 18 SM/ST/15L/R Module Front PanelSM/ST/15LH/R Module 19 SM/ST/15LH/R Module Front PanelSM/FC/15LH/R Module 20 SM/FC/15LH/R Module Front PanelMM/ST/85/T Module 21 MM/ST/85/T Module Front PanelSF1/ST/R Module 22 SF1/ST/R Module Front PanelSF2/ST/R Module 23 SF2/ST/R Module Front PanelSF1/FC/R Module 24 SF1/FC/R Module Front PanelSF2/FC/R Module 25 SF2/FC/R Module Front PanelCX/BNC/155/R Module BNCCX/DIN/155/R Module 27 CX/DIN/155/R Module Front PanelSTP/155/R Module 28 STP/155/R Module Front PanelSTP/155/T Module 29 STP/155/T Module Front PanelUTP/155/R Module 30 UTP/155/R Module Front PanelUTP/155/T Module 31 UTP/155/T Module Front PanelUTP/100/R Module 32 UTP/100/R Module Front PanelUTP/100/T Module 33 UTP/100/T Module Front Panel100BT/B Module 34 100BT/B100BT/R Module 35 100BT/R Module Front Panel10BT/B Module 36 10BT/B Module Front PanelControls and Indicators Chapter OperationJumper Locations and Functions Dry Contact Circuit and Connector for Alarms DC adapter ConnectionTurning on the AMC-101 ExampleAMC-101 Block Diagram Troubleshooting Procedures Normal OperationTurning off the AMC-101