RAD Data comm AMC-101 operation manual 0.25 dB/Km for 1550 nm modules

Page 22

Chapter 1 - IntroductionAMC-101Installation & Operation Manual

Table 1-1 Optical Module Characteristics (Cont.)

Module Name

Protocols

Fiber Type

Connector

Typical

Dynamic

Optical

Sensitivity

 

Supported

(Wavelength)

Type

Distance

Range

Power

 

 

 

 

 

 

 

(Typical)

 

 

 

 

 

 

 

 

 

SM/FC/13LH***

TAXI, FDDI,

9/125

FC-PC

60 Km /

33 dB

-2 dBm

-34 dBm

(LASER)

Fast Ethernet

(1300 nm)

 

37.2 mile

 

 

 

 

STS-3c/STM-1,

 

 

 

 

 

STS-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM/FC/15LH***

TAXI, FDDI,

9/125

FC-PC

110 Km /

33 dB

-2 dBm

-34 dBm

(LASER)

Fast Ethernet

(1550 nm)

 

68.2 mile

 

 

 

 

STS-3c/STM-1,

 

 

 

 

 

STS-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM/SC/13L**

TAXI, FDDI,

9/125

SC

40 Km /

30 dB

-12 dBm

-31 dBm

(LASER)

Fast Ethernet,

(1300 nm)

 

24.8 mile

 

 

 

 

STS-3c/STM-1,

 

 

 

 

 

 

 

 

 

 

 

 

 

STS-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM/ST/13**

TAXI, FDDI,

9/125

ST

25 Km /

30 dB

-15 dBm

-31 dBm

 

Fast Ethernet,

(1300 nm)

 

15.5 mile

 

 

 

 

STS-3c/STM-1,

 

 

 

 

 

 

 

 

 

 

 

 

 

STS-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM/ST/13L**

TAXI, FDDI,

9/125

ST

40 Km /

30 dB

-12 dBm

-31 dBm

(LASER)

Fast Ethernet,

(1300 nm)

 

24.8 mile

 

 

 

 

STS-3c/STM-1,

 

 

 

 

 

 

 

 

 

 

 

 

 

STS-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM/ST/13LH***

TAXI, FDDI,

9/125

ST

60 Km /

33 dB

-2 dBm

-34 dBm

(LASER)

Fast Ethernet,

(1300 nm)

 

37.2 mile

 

 

 

 

STS-3c/STM-1,

 

 

 

 

 

 

 

 

 

 

 

 

 

STS-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM/ST/15L**

TAXI, FDDI,

9/125

ST

50 Km /

30 dB

-12 dBm

-31 dBm

(LASER)

Fast Ethernet,

(1500 nm)

 

31 mile

 

 

 

 

STS-3c/STM-1,

 

 

 

 

 

 

 

 

 

 

 

 

 

STS-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM/ST/15LH***

TAXI, FDDI,

9/125

ST

110 Km /

33 dB

-2 dBm

-34 dBm

(LASER)

Fast Ethernet,

(1550 nm)

 

68.2 mile

 

 

 

 

STS-3c/STM-1,

 

 

 

 

 

 

 

 

 

 

 

 

STS-1

*Data Rates are switch-selectable from the front panel

**Transparent only

***Retimed only

Note

Typical distances based on attenuation of 0.4 dB/Km for 1300 nm modules

 

and 0.25 dB/Km for 1550 nm modules

1-12 Specifications

Image 22
Contents AMC-101 Page Warranty Safety Warnings Regulatory Information Declaration of Conformity Contents Operation List of Figures List of Tables General Retimed Modules TransparentFeatures STP UTPGeneral Applications Dissimilar Device ConnectivityWrap Dual Single Mode SM to Multimode MM Conversion Fddi and Fast Ethernet Operations Problem Fast Ethernet ApplicationsRepeater Half Duplex Connection over UTP 10 Point-to-Point Full Duplex Connection 12 Full Duplex Connection over UTP Specifications Optical Module Characteristics 0.25 dB/Km for 1550 nm modules Electrical Module Characteristics Introduction Specifications Unpacking Site RequirementsInstallation of a Installation Two UnitsCable Connections AC Power ConnectionGrounding AMC-101 Modules MM/SC/13/R ModuleMM/SC/13/T Module MM/SC/13/T Module Front PanelMM/ST/13/R Module MM/ST/13/R Module Front PanelMM/ST/13/T Module MM/ST/13/T Module Front PanelSM/ST/13/R Module 10 SM/ST/13/R Module Front PanelSM/ST/13/T Module 11 SM/ST/13/T Module Front PanelSM/FC/13/T Module 12 SM/FC/13/T Module Front PanelSM/ST/13L/R Module 13 SM/ST/13L/R Module Front PanelSM/ST/13L/T Module 14 SM/ST/13L/T Module Front PanelSM/SC/13L/R Module 15 SM/SC/13L/R Module Front PanelSM/ST/13LH/R Module 16 SM/ST/13LH/R Module Front PanelSM/FC/13LH/R Module 17 SM/FC/13LH/R Module Front PanelSM/ST/15L/R Module 18 SM/ST/15L/R Module Front PanelSM/ST/15LH/R Module 19 SM/ST/15LH/R Module Front PanelSM/FC/15LH/R Module 20 SM/FC/15LH/R Module Front PanelMM/ST/85/T Module 21 MM/ST/85/T Module Front PanelSF1/ST/R Module 22 SF1/ST/R Module Front PanelSF2/ST/R Module 23 SF2/ST/R Module Front PanelSF1/FC/R Module 24 SF1/FC/R Module Front PanelSF2/FC/R Module 25 SF2/FC/R Module Front PanelCX/BNC/155/R Module BNCCX/DIN/155/R Module 27 CX/DIN/155/R Module Front PanelSTP/155/R Module 28 STP/155/R Module Front PanelSTP/155/T Module 29 STP/155/T Module Front PanelUTP/155/R Module 30 UTP/155/R Module Front PanelUTP/155/T Module 31 UTP/155/T Module Front PanelUTP/100/R Module 32 UTP/100/R Module Front PanelUTP/100/T Module 33 UTP/100/T Module Front Panel100BT/B Module 34 100BT/B100BT/R Module 35 100BT/R Module Front Panel10BT/B Module 36 10BT/B Module Front PanelControls and Indicators Chapter OperationJumper Locations and Functions Dry Contact Circuit and Connector for Alarms DC adapter ConnectionTurning on the AMC-101 ExampleAMC-101 Block Diagram Normal Operation Troubleshooting ProceduresTurning off the AMC-101