RAD Data comm AMC-101 operation manual 10 SM/ST/13/R Module Front Panel

Page 33

AMC-101Installation & Operation Manual

Chapter 2 - Installation & Setup

 

 

SM/ST/13/R Module

Figure 2-10 SM/ST/13/R Module Front Panel

Wavelength:

1300 nm

Connector:

ST

Used with:

Single mode fiber

Protocols supported:

STS-3c, STM-1, STS-1, FDDI, TAXI and Fast

 

Ethernet

Timing mode:

Retimed

Coding method:

4B/5B, NRZ

Optical output into 9/125 fiber:

-15 dBm

Receiver sensitivity:

-31 dBm

Maximum input power:

-1 dBm

AMC-101 Modules

2-9

Image 33
Contents AMC-101 Page Warranty Safety Warnings Regulatory Information Declaration of Conformity Contents Operation List of Figures List of Tables Retimed Modules Transparent GeneralSTP UTP FeaturesDissimilar Device Connectivity General ApplicationsWrap Dual Single Mode SM to Multimode MM Conversion Fddi and Fast Ethernet Operations Fast Ethernet Applications ProblemRepeater Half Duplex Connection over UTP 10 Point-to-Point Full Duplex Connection 12 Full Duplex Connection over UTP Specifications Optical Module Characteristics 0.25 dB/Km for 1550 nm modules Electrical Module Characteristics Introduction Specifications Site Requirements UnpackingInstallation of a Two Units InstallationAC Power Connection Cable ConnectionsGrounding MM/SC/13/R Module AMC-101 Modules MM/SC/13/T Module Front Panel MM/SC/13/T ModuleMM/ST/13/R Module Front Panel MM/ST/13/R ModuleMM/ST/13/T Module Front Panel MM/ST/13/T Module10 SM/ST/13/R Module Front Panel SM/ST/13/R Module11 SM/ST/13/T Module Front Panel SM/ST/13/T Module12 SM/FC/13/T Module Front Panel SM/FC/13/T Module13 SM/ST/13L/R Module Front Panel SM/ST/13L/R Module14 SM/ST/13L/T Module Front Panel SM/ST/13L/T Module15 SM/SC/13L/R Module Front Panel SM/SC/13L/R Module16 SM/ST/13LH/R Module Front Panel SM/ST/13LH/R Module17 SM/FC/13LH/R Module Front Panel SM/FC/13LH/R Module18 SM/ST/15L/R Module Front Panel SM/ST/15L/R Module19 SM/ST/15LH/R Module Front Panel SM/ST/15LH/R Module20 SM/FC/15LH/R Module Front Panel SM/FC/15LH/R Module21 MM/ST/85/T Module Front Panel MM/ST/85/T Module22 SF1/ST/R Module Front Panel SF1/ST/R Module23 SF2/ST/R Module Front Panel SF2/ST/R Module24 SF1/FC/R Module Front Panel SF1/FC/R Module25 SF2/FC/R Module Front Panel SF2/FC/R ModuleBNC CX/BNC/155/R Module27 CX/DIN/155/R Module Front Panel CX/DIN/155/R Module28 STP/155/R Module Front Panel STP/155/R Module29 STP/155/T Module Front Panel STP/155/T Module30 UTP/155/R Module Front Panel UTP/155/R Module31 UTP/155/T Module Front Panel UTP/155/T Module32 UTP/100/R Module Front Panel UTP/100/R Module33 UTP/100/T Module Front Panel UTP/100/T Module34 100BT/B 100BT/B Module35 100BT/R Module Front Panel 100BT/R Module36 10BT/B Module Front Panel 10BT/B ModuleChapter Operation Controls and IndicatorsJumper Locations and Functions DC adapter Connection Dry Contact Circuit and Connector for AlarmsExample Turning on the AMC-101AMC-101 Block Diagram Troubleshooting Procedures Normal OperationTurning off the AMC-101