RAD Data comm RSD-20 Operating Procedure, Power Turn On, Operation, Power Turn Off

Page 19

RSD-20 OPERATOR'S MANUALOPERATION

Table 3.1

Control Functions

Control

Location

Function

Power switch (with lamp) ON/OFF

Rear Panel

Turns AC power ON or OFF

 

 

 

110/220 VAC Selector

Rear Panel

Selects main power source: 115 or 230 VAC

 

 

 

Four manual DISABLE push-button switches

Front Panel

Manually deactivates sub-channels

 

 

connected to defective terminals or modems.

 

 

A depressed push button disables the

 

 

sub-channel

 

 

 

 

 

Table 3.2

 

Indicator Functions

 

 

 

Indicator

 

Functions

 

 

 

Power

 

Green LED is ON when power is present and the DC power

 

 

supply is O.K.

 

 

 

Main

 

Yellow LED flickers according to main channel XMT data

 

 

 

Sub-channels Activity 1-4

 

Four yellow LEDs flicker according to sub-channels XMT data

 

 

 

Automatic Disable 1-4

 

Four red LEDs light when the corresponding sub-channel has

 

 

been automatically disabled (due to time-out)

 

 

 

3.3OPERATING PROCEDURE

3.3.1 Power Turn On

1)Make sure the power switch is turned to OFF.Set the 110/220 selector located on the rear panel to the main voltage used in your country. The white arrow should point to the correct main voltage.

2)Apply AC power by connecting the AC cord to the AC connector on the rear panel of the RSD-20 and then plug it into the AC source.

3)Turn the power switch located on the rear panel to ON. The power switch should light up, indicating that the main power is fed to the RSD-20 while the power LED (on the front panel) should light indicating that the internal power supply is O.K.

3.3.2 Operation

The RSD-20 operates unattended, unless it is required to manually disable one or more sub-channels.

3.3.3 Power Turn Off

To turn off the AC power to the RSD-20, simply switch off the power switch.

3.2

Image 19
Contents RSD-20 DUUDQW\ 6DIHW\DUQLQJV HFODUDWLRQRI&RQIRUPLW\ Table of Contents General IntroductionFunctional Description Specifications Physical IndicatorsPower OrderingAC Power InstallationPhysical Installation Electrical InstallationRear Panel Internal Switches and Strap SelectionRear Panel Installation Installation Synchronization on Main Channel Modem’s Clock System Synchronization and Clock DistributionRSD-20/V.35 Synchronization on Main Channel Modem ClockSynchronization on Internal Clock Synchronization on RSD-20 Internal ClockSynchronization on Sub-channel RSD-20Main and all sub-channels are DCE attached to DTEs RSD-20/X.21External Clock for more than one Sub-channel Main channel is DTE attached to a modemMain channel is DCE and sub-channels are mixed DTE and DCE Operation Controls and IndicatorsFront Panel Operation Operating ProcedurePower Turn On Power Turn OffRSD Malfunction Fault Isolation ProcedurePower Supply Operational Field Strapping ChangesIntroduction ContentionSUB-CHANNEL Disable Theory of Operation and ApplicationsRSD-20/V.35 Control SignalsMain Channel Control Signals Sub-channel Control SignalsRSD-20/X.21 Theory of Operation and Applications RSD-20 Operators Manual Theory of Operation and Applications RSD-20 Operating Modes ApplicationsAppendix a Table A.1 X21 Interface Signal DescriptionAppendix B Table B.1 Interface Signal Description