RAD Data comm RSD-20 operation manual Main channel is DCE and sub-channels are mixed DTE and DCE

Page 17

RSD-20 OPERATOR'S MANUAL

INSTALLATION

2.5.2.4Main channel is DCE and sub-channels are mixed (DTE and DCE)

In this mode one of the modems attached to the sub-channels (configured as DTE) should be attached to sub-channel 1, and the RSD baud rate should be strapped to CLK-1.

The DTEs attached to the main and sub-channels are synchronized to the RSD’s clock; the modems attached to the sub-channels are synchronized to their own clock; and the internal buffer compensates for the phase difference between the signal timing of the modem attached to sub-channel 1 to the rest of the modems.

NOTE

1.

Working with RSD’s internal clock is also possible but CLK-1 is

 

 

preferred.

 

2.

On DTE (sub-channels 1 to 4 and Main channel), the RSD-20 supplies

 

 

clock on pins 7 and 14 for DCE external clock (The DCE must support

 

 

external clock as in the ASM-20/8-X.21).

WARNING

Before plugging in this unit, the protective ground (earth) terminals must

 

be connected to the protective conductor of the (mains) power cord. The

 

mains plug should only be inserted in a socket outlet provided with a

protective ground (earth) contact. The protective action must not be negated by use of an extension cord (power cable) without a protective conductor (grounding).

Ensure that only fuses with the required rated current, and specified type (slow blow, 0.4A) are used for replacement. The use of repaired fuses, and the short-circuiting of fuse holders is strictly forbidden.

Whenever it is likely that the protection offered by fuses has been impaired, the instrument must be made inoperative and secured against unintended operation.

With the unit power turned on, operating personnel are not exposed to voltages in excess of 30 volts on any I/O pin, provided that the equipment to which the RSD-20 is connected is safe.

2.9

Image 17
Contents RSD-20 DUUDQW\ 6DIHW\DUQLQJV HFODUDWLRQRI&RQIRUPLW\ Table of Contents Functional Description IntroductionGeneral Specifications Power IndicatorsOrdering PhysicalPhysical Installation InstallationElectrical Installation AC PowerRear Panel Internal Switches and Strap SelectionRear Panel Installation Installation RSD-20/V.35 System Synchronization and Clock DistributionSynchronization on Main Channel Modem Clock Synchronization on Main Channel Modem’s ClockSynchronization on Internal Clock Synchronization on RSD-20 Internal ClockSynchronization on Sub-channel RSD-20External Clock for more than one Sub-channel RSD-20/X.21Main channel is DTE attached to a modem Main and all sub-channels are DCE attached to DTEsMain channel is DCE and sub-channels are mixed DTE and DCE Front Panel Controls and IndicatorsOperation Power Turn On Operating ProcedurePower Turn Off OperationPower Supply Fault Isolation ProcedureOperational Field Strapping Changes RSD MalfunctionSUB-CHANNEL Disable ContentionTheory of Operation and Applications IntroductionMain Channel Control Signals Control SignalsSub-channel Control Signals RSD-20/V.35RSD-20/X.21 Theory of Operation and Applications RSD-20 Operators Manual Theory of Operation and Applications RSD-20 Operating Modes ApplicationsAppendix a Table A.1 X21 Interface Signal DescriptionAppendix B Table B.1 Interface Signal Description