Direct Console Management

When you can see the self-test messages shown on screen properly, you can press <Enter> key to start console login operation. Go to Login Prompt section in next page directly.

Telnet Management

Use Telnet software to perform the management operation. The most convenient solution is using the built-in Telnet function in a Windows 95/98/ or NT PC. Enter into DOS window and invoke Telnet command :

>telnet xxx.xxx.xxx.xxx

to connect to the system unit. The specified xxx.xxx.xxx.xxx is the IP ad- dress of the system unit. A welcome message and login prompt are dis- played if the connection is established properly.

Login Prompt

The following figure illustrates the login screen:

---------------------------------------------

Welcome to Console login:admin password:***

---------------------------------------------

Username : admin

Factory default Password : 123

For security reason, the system supports a function to change the pass- word in setup menu. It is recommended to change the default password immediately after a successful login.

-30-

Image 30
Contents Modular Media Converter Center System KC-1300United States InternationalTrademarks Network Management Table of Contents IntroductionInstallation Console and Telnet OperationPage Introduction Features Technical Specifications System ModelAC Power Chassis Module Specifications System interface Update Firmware Unpacking System UnitsPage Management Module LED Indicators Color States Interpretation Console PortUTP Port Power Chassis Modules AC Power Chassis Specifications KC1300-ACDC Power Chassis Specifications KC1300-DC Removal of System Power Chassis Insertion of System Power Chassis Media Converter Slots Page Rack Mounting Management Functions Management Interface RS-232 / ProtocolProtocols Supported Protocols Name ReferenceSetup for Out-of-band Console Management Factory default settings of the Console port Setup for In-band Management Functions supported Management Objects Modify MonitorPower-on Self-test Cold StartLogin Prompt Direct Console ManagementTelnet Management When login successfully, a Setup menu is shown as follows IP Menu Set IP AddressView IP Status Contact Snmp MenuLocation CommunityView System Status View Converter Slots Status Slot status definitions are Restore Default Values Change user name and password Security ManagerDisplay current user name Update Firmware Following information are required for Tftp operationsSpecify Tftp server IP address Reboot SystemConfirm to update system flash memory Confirm to start downloadingSnmp Management Configuring Snmp Settings via Console Operation Snmp Private MIB Private MIB Objects Get RemarkSnmp Traps TrapName Event ofTrapGeneratedTrapName VarBind Start Browser Software and Making Connection Web BrowserSet IP Address for the System Unit Login to the System Unit LoginPage Converter Status Information includes System Status Administrator Menu Basic Page Snmp Entries System options Access right Snmp Entries Community StringsSnmp Entries Trap Managers Console Port Information Security Manager Image Refresh Time Update Firmware Reboot System Slot Icon Operations

KC-1300 specifications

KTI Networks KC-1300 is a state-of-the-art media converter designed to facilitate seamless and efficient data transmission between Ethernet and fiber optic networks. It is particularly well-regarded for its versatility, reliability, and the unique set of features that it brings to networking environments.

One of the standout characteristics of the KC-1300 is its capability to extend Ethernet segments over long distances via fiber optics. This eliminates the limitations imposed by traditional copper cabling, allowing organizations to connect devices that are located kilometers apart without sacrificing data integrity or network performance. The KC-1300 supports various types of fiber, including multimode and singlemode, making it adaptable for different networking needs.

The device is equipped with fast Ethernet ports that support a data transmission rate of up to 100 Mbps, ensuring rapid data transfer for both local and remote connections. The auto-negotiation feature enables it to automatically detect the best speed and duplex setting for optimal network performance. Additionally, the KC-1300 supports standard 10/100Base-Tx Ethernet interface, simplifying integration into existing network infrastructures.

In terms of technological features, the KC-1300 is built for durability and reliability. It has a robust design that is suitable for deployment in various environments, including industrial settings. Its integrated lightning protection safeguards against power surges, ensuring uninterrupted operation even in challenging conditions.

Another noteworthy feature of the KC-1300 is its user-friendly management capabilities. The device supports both DIP switches and LED indicators that facilitate easy configuration and monitoring. This transparency in operation allows network administrators to troubleshoot issues quickly, ensuring minimal downtime.

Furthermore, the KTI Networks KC-1300 is energy-efficient, adhering to the latest standards for power consumption, which contributes to lower operational costs for organizations while reducing their environmental footprint.

In summary, the KTI Networks KC-1300 is a powerful, flexible, and reliable media converter that not only enhances data transmission capabilities but also adapts seamlessly to diverse networking environments, making it an invaluable tool for modern enterprises looking to optimize their network performance. Its combination of advanced features and robust design positions it as a leading choice for businesses aiming to expand their connectivity options.