FE-2 SELF DIAGNOSTIC SOFTWARE
The identification of errors within the
Each time the software detects an error it is stored within the NVM. See Table 2.
Table 1
Error Message | LED | |
Code | ||
| ||
No error | 00 | |
Reserved | 01 | |
OCP ( Over Current Protection ) | 02 | |
Not Used | 03 | |
No Vertical Sync | 04 | |
IKR Error at power on | 05 | |
IIC bus clock and/or data lines low at power on | 06 | |
NVM no IIC bus acknowledge at power on | 07 | |
Not Used | 08 | |
Tuner no acknowledge at power on | 09 | |
|
| |
Sound Processor Error | 10 | |
|
| |
Jungle controller 8 volts error | 11 | |
|
|
Flash Timing Example : e.g. error number 3
StBy LED
ON | ON | ON |
| OFF | OFF |
How to enter into Table 2
1.Turn on the main power switch of the TV set and enter into the
‘Stanby Mode’.
2.Press the following sequence of buttons on the Remote Commander.
i+ | 5 | - |
|
(ON SCREEN | (DIGIT 5) | (VOLUME | (TV) |
DISPLAY) |
|
|
|
3.The following table will be displayed indicating the error count.
Table 2
ERROR MENU |
|
|
|
E02 | OCP | (0, 255) | 0 |
E03 | OVP N/A | (0, 255) | 0 |
E04 | VSYNC | (0, 255) | 0 |
E05 | IKR | (0, 255) | 0 |
E06 | IIC | (0, 255) | 0 |
E07 | NVM | (0, 255) | 0 |
E08 | JUNGLE | (0, 255) | 0 |
E09 | TUNER | (0, 255) | 0 |
E10 | SOUNDP | (0, 255) | 0 |
E11 | 8V | (0, 255) | 0 |
WORKING TIME |
|
|
|
HOURS |
|
| 2 |
MINUTES |
|
| 11 |
|
|
|
|
Note: To clear the error count data press ‘80’ on the Remote commander.
6