Layout of each control
V.STAT | Purity |
|
BMC (Hexapole)
3-3. Focus Adjustment
1.Receive a television broadcast signal.
2.Normalize the picture setting.
3.Adjust the focus control located on the flyback transformer to obtain the best focus at the centre of the screen.
Bring only the centre area of the screen into focus, the
focus to optimize the screen uniformly.
Focus
Screen
3-4. Screen (G2),White Balance
[Adjustment in the service mode using the remote commander]
G2 adjustment
1.Input a dot signal from the pattern generator.
2.Enter the ‘Service Mode’ by pressing ‘TEST’, ‘TEST’ and ‘38’
3.Whilst watching the picture, adjust the G2 control [SCREEN] located on the Flyback Transformer to the point where the OSD menu indication shows “OK”.
White balance adjustment for TV mode
1.Input an
2.Enter into the ‘Service Mode’ by pressing ‘TEST’, ‘TEST’ and ‘MENU’ on the Service Commander.
3.Select ‘Service’ from the on screen menu display and press the right arrow button on the remote commander.
4.The ‘Service’ menu will appear on the screen. [See Page 19]
5.Set the ‘Contrast’ to MAX.
6.Set the
7.Adjust the
8.Press the ‘OK’ button to write the data for each item.
9.Set the ‘Contrast’ to MIN.
10.Adjust the
11.Press the ‘OK’ button to write the data for each item.
18