Connections
SERIAL Terminals connection
The SERIAL terminal is used when the Plasma Display is controlled by a computer.
COMPUTER
| |
SERIAL | |
straight cable |
|
6 7 8 9
1 2 3 4 5
Pin layout for
Notes:
(1)Use the
(2)The computer shown is for example purposes only.
(3)Additional equipment and cables shown are not supplied with this set.
The SERIAL terminal conforms to the
The computer will require software which allows the sending and receiving of control data which satisfies the conditions given below. Use a computer application such as programming language software. Refer to the documentation for the computer application for details.
Communication parameters
Signal level | |
|
|
Synchronization method | Asynchronous |
Baud rate | 9600 bps |
|
|
Parity | None |
|
|
Character length | 8 bits |
Stop bit | 1 bit |
|
|
Flow control | – |
Details | |||
| 2 |
| R X D |
| 3 |
| T X D |
| 5 |
| GND |
4 | • | 6 | Non use |
| 7 |
| Shorted |
| 8 |
| |
|
|
| |
1 | • | 9 | NC |
Command
Basic format for control data |
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||
|
|
|
|
|
|
|
|
| Command | Parameter | Control details | |||||||||||||||||
The transmission of control data from the computer starts | ||||||||||||||||||||||||||||
with a STX signal, followed by the command, the | PON | None | Power ON | |||||||||||||||||||||||||
parameters, and lastly an ETX signal in that order. If there | POF | None | Power OFF | |||||||||||||||||||||||||
are no parameters, then the parameter signal does not |
|
|
| |||||||||||||||||||||||||
AVL | ** | Volume 00 ~ 63 | ||||||||||||||||||||||||||
need to be sent. |
|
|
|
|
|
|
|
|
|
| Audio MUTE OFF | |||||||||||||||||
|
|
|
|
|
|
|
|
| AMT | 0 | ||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 | Audio MUTE ON | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
STX |
| C1 | C2 | C3 |
| : |
|
| P1 | P2 | P3 | P4 | P5 |
| ETX |
|
|
|
| |||||||||
IIS | None | Input select (toggle) | ||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| Colon |
| Parameter(s) |
|
| End |
| VID | VIDEO Mode | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||
Start |
|
|
| (1 - 5 bytes) | (03h) |
| YP1 | COMPONENT / RGB mode (processed as | ||||||||||||||||||||
|
|
|
| |||||||||||||||||||||||||
(02h) |
|
|
| command (3bytes) |
|
|
|
|
|
|
|
|
|
|
| a Y/PB/PR or RGB signals as set by this unit) | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RG1 | PC mode | |
Notes: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| DAM | None | Screen mode select (toggle) | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| NORM | NORMAL (4:3) | ||||
(1) If multiple commands are transmitted, be sure to wait |
| |||||||||||||||||||||||||||
| ZOOM | ZOOM | ||||||||||||||||||||||||||
for the response for the first command to come from |
| |||||||||||||||||||||||||||
| FULL | FULL | ||||||||||||||||||||||||||
this unit before sending the next command. |
|
|
| |||||||||||||||||||||||||
|
|
| JUST | JUST | ||||||||||||||||||||||||
(2) If an incorrect command is sent by mistake, this unit will |
| |||||||||||||||||||||||||||
| SELF | Panasonic AUTO | ||||||||||||||||||||||||||
send an “ER401” command back to the computer. |
| |||||||||||||||||||||||||||
|
|
| ||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| With the power off, this display responds to PON command only. |
17