Panasonic TH-50PH11UK, TH-42PH11UK manual Options Adjustments, Menu&Enter

Page 40

Options Adjustments

Item

 

 

 

 

 

Adjustments

 

Off

PC

INPUT1

INPUT2

INPUT3

 

Locks the input switch operation.

 

 

 

Notes:

 

 

 

 

 

 

• Only the adjusted signal is displayed (see page 15).

INPUT lock

• Signal can be displayed when the Terminal board is installed.

• Input switch can be used when this is set to “Off”.

 

 

• In two screen display mode, if anything other than “Off” is set, the value will be fixed as the value input in

 

the single screen display mode.

 

 

 

• When a dual input terminal board is attached, A or B is displayed depending on the selected input signal.

 

(Ex. INPUT1A, INPUT1B)

 

 

 

Off

MENU&ENTER

On

 

 

 

Off: All the buttons on main unit can be used.

 

MENU&ENTER: Locks

and

buttons on main unit.

 

 

 

 

MENU

 

ENTER/

 

 

 

 

 

Button lock

On: Locks all the button on main unit.

 

 

 

 

Sets Button lock with the unit buttons in the following procedure.

 

 

 

Off: Press

four times→Press

four times→Press

four times→Press

 

 

MENU&ENTER: Press

 

INPUT

 

four times→Press

ENTER/

 

 

four times→Press

four times→Press

 

 

On: Press

 

ENTER/

 

 

four times→Press

INPUT

 

ENTER/

 

four times→Press

four times→Press

 

 

 

 

 

 

 

ENTER/

 

 

 

ENTER/

 

 

Off

User1

User2

User3

 

 

 

 

 

Off:

You can use all of the buttons on the remote control.

 

 

Remocon User level

User1:You can only use

,

, ,

, ,

buttons on the remote control.

 

 

User2:You can only use

button on the remote control.

 

User3:Locks all the buttons on remote control.

 

Off:

Sets normal two screen display mode (see page 19).

 

On:

Sets Advanced PIP mode (see page 20).

Advanced PIP

Notes:

 

 

When “INPUT lock” is “On”, you cannot use all the two screen display functions.

, buttons are unavailable during Advanced PIP mode operation.

 

Enable:

Enables the “Off-timer function”.

Off-timer function

Disable:

Disables the “Off-timer function”.

 

Note:

 

When “Disable” is set, the Off-timer is cancelled.

 

Normal

Standby

On

 

Sets the power mode of the unit for when the power recovers from failure or after plugging off and in again.

Initial Power Mode

Normal: Power returns in as the same state as before the power interruption.

Standby: Power returns in standby mode. (Power Indicator : red/orange)

 

 

On:

 

Power returns in power On. (Power Indicator : green)

 

Note: When using multiple displays, “Standby” is preferred to be set in order to reduce a power load.

 

Sets panel ID number when panel is used in “Remote ID” or “Serial ID”.

ID select

Set value range: 0 - 100

 

 

 

 

 

 

(Standard value: 0)

 

 

 

 

 

 

The setting of this menu is valid only when using ID remote control.

Remote ID

Off:

Disables ID remote control functions. You can use normal remote control operations.

 

On:

Enable ID remote control functions.

 

Sets the panel ID Control.

 

 

 

 

 

Serial ID

Off:

Disables external control by the ID.

 

On:

Enables the external control by the ID.

 

Adjusts the image display size on screen.

 

Off:

Sets the normal image display size on screen.

 

On:

Sets the image display size approximately 95 % of the normal image display.

 

 

 

Off

 

 

On

Display size

Notes:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• This setting is valid only when the input signals are as follows;

 

 

NTSC, PAL, SECAM, M.NTSC, PAL60, PAL-M, PAL-N (BNC Dual Video Terminal Board (TY-FB9BD))

 

525i, 525p, 625i, 625p, 750/60p, 750/50p, 1125/60i, 1125/50i, 1125/24sF, 1125/25p, 1125/24p, 1125/30p,

 

1125/60p, 1125/50p, 1250/50i (Component Video, RGB, DVI, SDI, HDMI)

 

• This setting is invalid when two screen display, digital zoom or Multi display is selected.

 

• When “Display size” is set to “On”, “H-POS” and “V-POS” in “POS. /SIZE” can be adjusted.

 

• Refer to each board’s operating instruction for DVI, SDI, HDMI’s corresponding signals.

40

Image 40
Contents English Español Operating Instructions Manual de instruccionesModel No. Número de modelo Risk of Electric Shock Do not Open Important Safety Instructions Table of Contents Canadian Notice FCC CautionTrademark Credits Safety Precautions When using the Plasma DisplayMaintenance Safety Precautions / MaintenanceSetup AC Power Supply CordAccessories Supplied AccessoriesRemote Control Batteries Connections AC cord fixingCable fixing band SeePC Input Terminals connection Signal Names for Mini D-sub 15P ConnectorConnections Signal names for D-sub 9P connector CommandSerial Terminals connection Communication parametersHdmi connection Component / RGB connectionRCA-BNC DVDConnecting the AC cord plug to the Plasma Display Power on / OFFConnecting the plug to the Wall Outlet Power on / OFF When first switching on the unitPresent Time Setup OSD LanguageSelecting the input signal Initial selectionsSelecting the On-Screen Menu Language INPUT1 INPUT2A INPUT2B INPUT3 PCRemote control sensor Volume Adjustment Main Power On / Off Switch Power IndicatorBasic Controls Menu Screen on / OFFBasic Controls On OFFAspect Controls All Aspect modePanasonic Auto Multi PIP Aspect ControlsAdvanced PIP Digital Zoom Display the operation guidePosition Select the magnification required for the enlarged displayOn-Screen Menu Display Adjusting POS. /SIZE Picture Adjustments StandardDynamic CinemaAdvanced Settings Picture AdjustmentsPress to exit from adjust mode Sound AdjustmentSDI Sound Output Present Time Setup SET UP TimerSetup of Screensaver Time Start settingScreensaver For preventing image retention Function selectionSide BAR Adjust Reduces screen image retentionScreensaver For preventing image retention OFF Dark MID BrightReduces power consumption Addition sign Selected Input Customizing the Input labelsLandscape Portrait SET UP for Multi Display How to setup Multi DisplayOFF Display Number locations for each arrangement ExamplesID Remote Control Function SET UP for Multi DisplayID remote control button operation ID CancellationComponent / RGB in Select SET UP for Input SignalsYUV / RGB in Select SET UP for Input Signals Signal menu3D Y/C Filter For Ntsc AV images XGA Mode Mode FunctionColor System / Panasonic Auto PulldownPress to adjust Refresh RateNoise Reduction Advanced NRSetting RGB sync signal Input signal displaySync Options Adjustments INPUT1 INPUT2 INPUT3Options Adjustments MENU&ENTERNormalization 43→H-FILL→ZOOM→FULL→JUSTWeekly Command Timer Press Action buttonProgram number Program Edit screenPress to select Time / Command Time Set the time to execute a command programShipping condition Press to set each itemTroubleshooting Plasma Display panelList of Aspect Modes FullVIDEO/COMPONENT/RGB/PC input signals Video input HdmiCommand list of Weekly Command Timer Specifications TH-42PH11UK TH-50PH11UKPanasonic Professional Flat Panel Display Limited Warranty For the U.S.ALimited Warranty Statement For CanadaPage Page Page Page Page Page Page Customer’s Record Panasonic Professional Display CompanyExecutive Office Panasonic Canada Inc