5FUNCTION/ENTER button

This button is used to enter changes or settings while a menu is displayed.

If there is no menu display, the button’s function changes depending on which FUNCTION item on the menu is selected. One of the following three items can be selected. (Refer to page 19)

UNDEF: No function is allocated to this item.

HV DELAY: Image blanking is displayed. Each time the button is pressed, the blanking display is switched by one setting in the following sequence: H blanking display

>V blanking display > H and V blanking display > no blanking display.

WFM ON/OFF: The Y signal (luminance) waveform is displayed at the bottom right of the image. When the button is pressed again, the display is cleared.

When waveforms are displayed in the 16:9 mode, the image displayed on the screen moves to the upper part of the screen so that it will not be superimposed onto the waveform display.

>

WFM

WFM function OFF

WFM function ON

The image remains unchanged in the 4:3 mode.

>

WFM

WFM function OFF

WFM function ON

<Notes>

In order for this function to be used, it is necessary to select WFM as the FUNCTION item setting on the SYSTEM CONFIG screen, and then select FUNCTION as the WFM item setting.

The WFM function is a simplified one and, as such, finely detailed waveforms may not be displayed accurately.

In addition, differences in the input signal format or input function may result in the display having a different horizontal width.

1 2 3 4

PEAK/PHASE CHROMA BRIGHT CONTRAST

4Image controls

These controls are used to adjust the peaking/colour phase, chroma, brightness and contrast. When a control is pushed in, it pops out to enable adjustment. When a numerical value is changed from the default setting, the lamp to the left of the control lights.

The adjustments performed using these controls are valid only when the controls are in the “out” position, and when a control is pushed back in, the value adjusted by that control is returned to its default setting.

1PEAK/PHASE (PEAKING/PHASE)

This control is used to adjust the peaking or phase. Which of these is to be adjusted is set using the PEAKING/PHASE item on the SYSTEM CONFIG screen.

PEAKING

This function is selected when the monitor is to be used as a viewfinder.

It is used to set the edge sharpness. Any value from 0 to 30 can be set: the higher the value, the sharper the edges. The default setting is 0.

PHASE

This function is selected when the monitor is to be used as a monitor.

It is used to set the colour phase of the screen. Any value from 0 to 60 can be set. The default setting is 30.

<Notes>

When the blue-only function is ON, the control functions as the PHASE control regardless of the setting.

The colour phase cannot be adjusted when RGB signals are input.

2CHROMA

This control is used to adjust the image chroma. Any value from 0 to 60 can be set. The default setting is 30.

<Note>

The chroma cannot be adjusted when RGB signals are input or when the MONO setting is ON.

3BRIGHT

This control is used to adjust the image brightness. Any value from 0 to 60 can be set. The default setting is 30.

However, the brightness cannot be adjusted when blanking is displayed using the HV DELAY function.

4CONTRAST

This control is used to adjust the image contrast. Any value from 0 to 60 can be set. The default setting is 50.

6

Image 6
Contents BT-LH900E Liquid Crystal Video MonitorRefer servicing to qualified service personnel For your safetyCover. No user serviceable parts inside To reduce the risk of electric shock, do not removeContents Precautions for useIntroduction Tally lamps Power LEDParts and their functions Function buttonsWFM Image controlsFUNCTION/ENTER button WFM function OFF= SDI output connector Battery holderAnalogue component/RGBS connectors Main controls dedicated connectorPlug in the connector until it clicks into place Relocating the main controlsUsing a V-mount battery pack Supplying the powerUsing the Anton Bauer battery pack ReferencePin no Signal Cosmetic screws+12V Battery voltage display How to use the on-screen menusChannel and signal format Menu displayBattery voltage display Concerning the signal formatsImage control display Menu operations Menu operationsMENU/EXIT button Loading the user data User dataSaving the user data Menuexit Xwsel ENDisplayed in greenMenu configuration Main MenuUnderlined setting indicates the factory setting mode Menu itemsTypes of markers MarkersCentre marker Color Temp Gamma SelectGPI SharpnessFunction User ModeBacklight UndefYpbpr *1 FormatVideo *1 YpbprLevel LocalenableComponent RGB-SYNCRemote specifications GPI connectorList of functions allocated ± Crcc error Error and warning displaysRS-232C connector ± Inverter errorMaintenance timeframe and implementation item Maintenance and inspectionsNecessity for periodic maintenance and servicing Part QuantitySignal formats supported SpecificationsInput connectors Accessories provided with the monitorMemo Memo S1103T0 @