USER menu
<INTERFACE>
Item
No. Superimposed display
2 0 0 PARA RUN
201 9P SEL
Setting
No. | Superimposed |
| display |
0000 | DIS |
0001 | ENA |
0000 | OFF |
0001 | ON |
Description
This selects whether two or more VTRs are to be operated in synchronization.
0:No operation in synchronization
1:Operation in synchronization
<Note>
When operating two or more VTRs in synchronization, set item 200 of all the VTRs to 0001.
This selects whether the 9P connector functions when the REMOTE/LOCAL switch has been set to REMOTE.
0:Do not function
1:Function
2 0 2 ID SEL
2 0 3 25P SEL
204RS232C SEL
20 5 BAUD RATE
2 0 6 | DATA |
| LENGTH |
2 0 7 | STOP BIT |
2 0 8 | PARITY |
2 0 9 RETURN ACK
0000 | OTHER | This selects the ID information which is returned to the | |
0001 | DVCPRO | controller. | |
|
| 0: 20 25H | |
|
| ’ | |
0000 | OFF | 1: DVCPRO s, own ID is returned (F0 33H). | |
This selects whether the PARALLEL (25P) connector functions | |||
0001 | ON when the REMOTE/LOCAL switch has been set to REMOTE. | ||
|
| 0: Does not function | |
0000 | OFF | 1: Functions | |
These settings are for selecting whether the | |||
0001 | ON connector is to function when the REMOTE/LOCAL switch is | ||
|
| set to REMOTE. | |
|
| 0: Connector does not function. | |
0000 | 300 | 1: Connector functions. | |
These settings are for selecting the | |||
0001 | 600 | speed (baud rate). | |
0002 | 1200 |
| |
0003 | 2400 |
| |
0004 | 4800 |
| |
0005 | 9600 |
| |
0000 | 7 | These settings are for selecting the | |
0001 | 8 | (Unit: bit) | |
0000 | 1 | These settings are for selecting the | |
0001 | 2 | (Unit: bit) | |
0000 | NON | These settings are for selecting the none, odd or even for the | |
0001 | ODD | ||
0002 | EVEN | 0: Parity bit is not used. | |
|
| 1: An odd number of bits is used for the parity system. | |
0000 | OFF | 2: An even number of bits is used for the parity system. | |
These settings are for selecting whether the ACK code is to be | |||
0001 | ON | ||
returned when a command is received from |
0: ACK code is not returned.
1: ACK code is returned.
The underline on the setting item denotes the initial setting.