5.0 SPECIFICATIONS
NOTE: It is not recommended using 24 VAC in applications requiring heat- ers/blower because of the excessive current draw that may exceed Class 2 transformer applications.
ELECTRICAL
Enclosure Back Box
Input Voltage: | 24 VAC or 120 VAC |
Power Requirements | |
Receiver/Driver: | 48 vA for 24 VAC and 120 VAC dome drives |
Blower |
|
continuous duty: | One (1) at 30 cfm, 1.92 watts, 24 VDC |
| One (1) at 33 cfm, 6.7 watts, 120 VAC 60 Hz |
| One (1) at 27 cfm, 8.9 watts 230 VAC 50 Hz |
Heaters |
|
24 VAC: | 120 watts total |
120 VAC: | 135 watts total |
230 VAC: | 105 watts total |
| Thermostatically controlled; activates ON at 40°F (4.4°C) and |
| OFF at 60°F (15.56°C) |
Power cord: | Not supplied; use |
| 230 VAC supply input |
Power cable: | Not supplied: must conform to local and national electrical |
| codes |
GENERAL |
|
Enclosure |
|
Environment: | Indoor or outdoor (depending on model ordered) |
Dimensions: | See Figures 12 and 13 |
Construction |
|
Back box: | Aluminum |
Cap: | Aluminum |
Bezel: | Aluminum |
Trim Ring: | ABS/aluminum |
Finish: | The following are standard colors; consult factory for optional |
| colors |
Outdoor |
|
Pendant | Light gray |
Indoor |
|
Suspended/ |
|
Hard Ceiling | White (back box) and eggshell white (faceplate, trim ring and |
| bezel) |
Pendant | Black |
Temperature Range
Indoor models: 32° to 120°F (0° to 48.89°C)
Outdoor models:
(Design and product specifications subject to change without notice.)
26 | Pelco Manual |