3.2.3 Heater/Blower Kit Field Installation

The kits are shipped partially assembled, to complete assembly and to install the heater/blower kit perform the following steps:

1.Place the fan over the four (4) unused internally threaded standoffs located on the back plate (refer to Figure 11). Note the arrow indicating the air flow direc- tion of the fan, installing with arrow pointing “away” from back plate.

2.Place the heater assembly over the fan aligning the four (4) holes in the plate with the holes in the fan and the standoffs.

3.Install the four (4) #6 lock washers and screws through the plate and the fan threading the screws into the standoffs.

4.Mounting through one hole of the thermostat mounting tab, attach the thermo- stat to the standoff of the terminal block on the end nearest the fan using the 6- 32 x 3/8" screw (see Figure 11).

5.Connect the terminated wires to the terminal block as shown in Figures 3 through 6 depending on back box configuration.

3.3DOME DRIVE INSTALLATION

Back box installation is now complete. Proceed with the installation of the dome drive or fixed mount unit. Refer to the manual provided with the dome drive or fixed mount for further installation instructions.

20

Pelco Manual C454M-C (1/98)

Image 20
Contents Listed Contents List of Illustrations List of TablesRevision History Manual # Date CommentsThis page intentionally left blank Product and/or manual may bear the following marks Important Safeguards and WarningsGeneral Unpacking Instructions Recommended ToolsSuspended Ceiling Models Hard Ceiling ModelsDescription ModelsIndoor, Suspended-Grid Ceiling Indoor, Hard CeilingIndoor, Pendant Outdoor, PendantInstallation Proceed to .2, Wiring InstructionsMounting Suspended Ceiling MountingOptional Backup Plate Installation Hard Ceiling MountingBackup Plate Installation Pendant MountingWiring Instructions Proceed to .3, Dome Drive InstallationOn-Board Receiver/Driver TXD+ RXD+RG6/U LoadPelco Manual C454M-C 1/98 Pelco Manual C454M-C 1/98 Pelco Manual C454M-C 1/98 Hard-Wire or Remote Receiver/Driver Non-Preset ModelsPreset Non-SL Models Preset SL ModelsWiring Diagram, Hard-Wire Control with Heater Wiring Diagram, Hard-Wire Control without Heater Heater/Blower Kit Field Installation Dome Drive InstallationExploded Assembly Diagrams Pelco Manual C454M-C 1/98 MRCA4000COMP Back Plate Exploded Assembly Diagram TRB6TBV-10-OE ZH1/4CLIPSSTRBJ6-2 TRBTC6-10-PFHSpecifications Power RequirementsEnclosure Back Box EnclosureSuspended/Hard Ceiling Dimension Drawings Warranty and Return Information Warranty