BB14E100

Indoor, black, pendant-mount back box; smoked dome; hard-

 

wire control. (CE, UL)

BB14E101

Indoor, black, pendant-mount back box; clear dome; hard-wire

 

control. (CE, UL)

BB14E110

Indoor, black, pendant-mount back box; smoked dome; 120

 

VAC input. (UL)

BB14E111

Indoor, black, pendant-mount back box; clear dome; 120 VAC

 

input. (UL)

BB14E120

Indoor, black, pendant-mount back box; smoked dome; 24

 

VAC input. (CE, UL)

BB14E121

Indoor, black, pendant-mount back box; clear dome; 24 VAC

 

input. (CE, UL)

BB14E130

Indoor, black, pendant-mount back box; smoked dome; 230

 

VAC input. (CE)

BB14E131

Indoor, black, pendant-mount back box; clear dome; 230 VAC

 

input. (CE)

Outdoor, Pendant

BB14E200

Outdoor, gray, pendant-mount back box; smoked dome; hard-

 

wire control. Includes 120 VAC heater and blower. (CE)

BB14E200-2

Outdoor, gray, pendant-mount back box; smoked dome; hard-

 

wire control. Includes 24 VAC heater and blower. (CE)

BB14E200-3

Outdoor, gray, pendant-mount back box; smoked dome; hard-

 

wire control. Includes 230 VAC heater and blower. (CE)

BB14E201

Outdoor, gray, pendant-mount back box; clear dome; hard-wire

 

control. Includes 120 VAC heater and blower. (CE)

BB14E201-2

Outdoor, gray, pendant-mount back box; smoked dome; hard-

 

wire control. Includes 24 VAC heater and blower. (CE)

BB14E201-3

Outdoor, gray, pendant-mount back box; smoked dome; hard-

 

wire control. Includes 230 VAC heater and blower. (CE)

BB14E210

Outdoor, gray, pendant-mount back box; smoked dome; 120

 

VAC input. Includes 120 VAC heater and blower. (UL)

BB14E211

Outdoor, gray, pendant-mount back box; clear dome; 120 VAC

 

input. Includes 120 VAC heater and blower. (UL)

BB14E220

Outdoor, gray, pendant-mount back box; smoked dome; 24

 

VAC input. Includes 24 VAC heater and blower. (CE, UL)

BB14E221

Outdoor, gray, pendant-mount back box; clear dome; 24 VAC

 

input. Includes 24 VAC heater and blower. (CE, UL)

BB14E230

Outdoor, gray, pendant-mount back box; smoked dome; 230

 

VAC input. Includes 230 VAC heater and blower. (CE)

BB14E231

Outdoor, gray, pendant-mount back box; clear dome; 230 VAC

 

input. Includes 230 VAC heater and blower. (CE)

8

Pelco Manual C454M-C (1/98)

Image 8
Contents Listed Contents List of Illustrations List of TablesRevision History Manual # Date CommentsThis page intentionally left blank Product and/or manual may bear the following marks Important Safeguards and WarningsGeneral Unpacking Instructions Recommended ToolsSuspended Ceiling Models Hard Ceiling ModelsDescription ModelsIndoor, Suspended-Grid Ceiling Indoor, Hard CeilingIndoor, Pendant Outdoor, PendantInstallation Proceed to .2, Wiring InstructionsMounting Suspended Ceiling MountingOptional Backup Plate Installation Hard Ceiling MountingBackup Plate Installation Pendant MountingWiring Instructions Proceed to .3, Dome Drive InstallationOn-Board Receiver/Driver TXD+ RXD+RG6/U LoadPelco Manual C454M-C 1/98 Pelco Manual C454M-C 1/98 Pelco Manual C454M-C 1/98 Hard-Wire or Remote Receiver/Driver Non-Preset ModelsPreset Non-SL Models Preset SL ModelsWiring Diagram, Hard-Wire Control with Heater Wiring Diagram, Hard-Wire Control without Heater Heater/Blower Kit Field Installation Dome Drive InstallationExploded Assembly Diagrams Pelco Manual C454M-C 1/98 MRCA4000COMP Back Plate Exploded Assembly Diagram TRB6TBV-10-OE ZH1/4CLIPSSTRBJ6-2 TRBTC6-10-PFHSpecifications Power RequirementsEnclosure Back Box EnclosureSuspended/Hard Ceiling Dimension Drawings Warranty and Return Information Warranty