Pelco C454M-C operation manual Pendant Mounting, Backup Plate Installation

Page 11

3.1.3 Pendant Mounting

NOTE: The length of pipe used may effect noticeable motion on the video display. If this occurs additional sup- port of the pipe by bracing, guy wir- ing, etc. will be required.

NOTE: For outdoor models apply pipe thread sealant to the pipe threads prior to assembly.

The pendant back box is designed to be suspended from a suitable length of 1-1/2” pipe threaded at both ends. This pipe can be interfaced to the IWM Series or IDM4018 wall mounts or to the MRWA wall adapter mount or MRCA ceiling adapter mount.

To install the pendant type back box, perform the following steps:

1.Select and install the mount of choice according to the instructions provided with the mount. This may be a good time to route any needed wiring through the mount. Refer to Section 3.2, WIRING INSTRUCTIONS.

2.Select the appropriate length of pipe (2-1/2" minimum length) and thread into the mount. Tighten to approximately 30 ft/lb and tighten any locking means that may be provided on the mount.

3.Slide the back box “cap” up the pipe.

On outdoor units first slide one (1) of the two (2) O-rings up the pipe, followed by the “cap” and the second O-ring.

On indoor models while holding the “cap” in place, bring the back box into place and engage the threaded flange on the back box with the pipe. (Be sure to back out the locking screw in the flange prior to this.)

4.Spin the back box onto the pipe. The latches inside the back box may be used as handles to provide a light torque to the box (approximately 20 ft/lb). Tighten the lock screw.

5.Lower the “cap” onto the top of the back box. On outdoor models also lower the external O-ring until it contacts the “cap”.

Proceed to Section 3.2, WIRING INSTRUCTIONS.

Figure 2. Backup Plate Installation

Pelco Manual C454M-C (1/98)

11

Image 11
Contents Listed Contents Manual # Date Comments List of IllustrationsList of Tables Revision HistoryThis page intentionally left blank Product and/or manual may bear the following marks Important Safeguards and WarningsGeneral Hard Ceiling Models Unpacking InstructionsRecommended Tools Suspended Ceiling ModelsIndoor, Hard Ceiling DescriptionModels Indoor, Suspended-Grid CeilingOutdoor, Pendant Indoor, PendantSuspended Ceiling Mounting InstallationProceed to .2, Wiring Instructions MountingHard Ceiling Mounting Optional Backup Plate InstallationPendant Mounting Backup Plate InstallationTXD+ RXD+ Wiring InstructionsProceed to .3, Dome Drive Installation On-Board Receiver/DriverLoad RG6/UPelco Manual C454M-C 1/98 Pelco Manual C454M-C 1/98 Pelco Manual C454M-C 1/98 Preset SL Models Hard-Wire or Remote Receiver/DriverNon-Preset Models Preset Non-SL ModelsWiring Diagram, Hard-Wire Control with Heater Wiring Diagram, Hard-Wire Control without Heater Dome Drive Installation Heater/Blower Kit Field InstallationExploded Assembly Diagrams Pelco Manual C454M-C 1/98 MRCA4000COMP Back Plate Exploded Assembly Diagram TRBTC6-10-PFH TRB6TBV-10-OEZH1/4CLIPSS TRBJ6-2Enclosure SpecificationsPower Requirements Enclosure Back BoxSuspended/Hard Ceiling Dimension Drawings Warranty Warranty and Return Information