Pelco FR8332, C2652M manual Inserting Cage Nuts

Page 11

2.Mount one front-mount support rail with one rear-mount support rail back-to-back, and attach the rails using three 8-32 x 0.375-inch Phillips truss head screws (refer to Figure 9). Leave the screws loose until the support rails are attached to the rack in step 7.

(3) SCREWS, 8-32 X 0.375 PHILLIPS TRUSS HEAD

Figure 9. Assembling a Support Rail

3.Repeat step 2 for the other set of front-mount and rear-mount support rails.

4.If you are installing the unit into a square-hold rack, continue with this step; otherwise, skip this step and proceed to step 5. Insert 10 cage nuts into the square-hole rack (refer to Figure 10). Align the top and bottom cage nuts on the front racks with the top and bottom cage nuts on the rear racks.

CAGE NUT

CAGE NUT

 

ALIGN

 

ALIGN

FRONT-MOUNT RAIL

REAR-MOUNT RAIL

Figure 10. Inserting Cage Nuts

5.Attach one support rail assembly to the equipment rack in the desired location as follows (refer to Figure 11): NOTE: The support rail assemblies are identical and may be used on either the right or left side of the rack.

a.Position the ear of the front-mount rail against the front of the equipment rack, and align the top and bottom holes in the ear of the rail with the threaded holes (or cage nuts) in the rack.

b.Using two 10-32 x 0.5-inch Phillips flat head screws, attach the ear of the rail to the front of the rack. Insert the screws from the outside of the rack, pointing toward the back of the rack.

c.Adjust the rails to the correct depth of the equipment rack by sliding the rear-mount rail to the back of the equipment rack.

C2652M (1/08)

11

Image 11
Contents FT8332/FR8332 Fiber Transmitter Receiver List of Tables ContentsList of Illustrations Important Safety Instructions Radio and Television Interference Regulatory NoticesMultimode Models Product OverviewDescription ModelsFront Panel of FT8332/FR8332 Unit with Bezel Front PanelIllustrates the rear panel of the FT8332/FR8332 unit Rear PanelPackage Contents InstallationShown Actual Size Mounting the TRANSMITTER/RECEIVER Into a Rack Mounting the TRANSMITTER/RECEIVERInserting Cage Nuts Rack Front Mounting the TRANSMITTER/RECEIVER to a Wall Pin Number ConnectionsVideo Present LED TroubleshootingTroubleshooting FRONT-PANEL Indicators Removing the BezelRX Optical Link Loss Specifications onVideo SpecificationsSingle-Mode 9/125 µm Model Number Optical MaximumTransmitter Multimode 62.5/125 µmProduct Warranty and Return Information ISO9001