FRONT PANEL

The front panel of the FT8332/FR8332 unit provides a removable bezel. Figure 2 illustrates the front of the unit with the bezel attached. Figure 3 illustrates the front of the unit with the bezel removed.

NOTE: The Contact Closure Activation and Data Activity LEDs shown in Figure 3 are not used.

Figure 2. Front Panel of FT8332/FR8332 Unit with Bezel

Figure 3. Front Panel of FT8332/FR8332 Unit Without Bezel

ìPower LED: Lights the Pelco badge blue to indicate that power is being applied to the unit.

NOTE: When the bezel is removed from the front panel, the Power LED does not light to indicate that power is being applied to the unit.

îKeylock: Locks/unlocks the front bezel.

ïLED Activation Switch: Lights the front-panel Optical Link and Video Present LEDs as appropriate when the bezel is removed.

NOTE: When the bezel is attached to the front panel, the Optical Link and Video Present LEDs do not light.

ñTX Optical Link LEDs 1-4:(Applicable to FT8332 transmitter only) Light to indicate laser status. Green indicates that the laser is operating properly. Flashing red indicates that the laser has shut down.

NOTE: The TX Optical Link LEDs operate independently of one another. TX Optical Link LED 1 indicates the laser status of channels 1-8.

TX Optical Link LED 2 indicates the laser status of channels 9-16. TX Optical Link LED 3 indicates the laser status of channels 17-24. TX Optical Link LED 4 indicates the laser status of channels 25-32.

óRX Optical Link LEDs 1-4:(Applicable to FR8332 receiver only) Light to indicate optical signal status. Green indicates that the optical signal is being received. Red indicates that the optical signal is not being received.

NOTE: The RX Optical Link LEDs operate independently of one another. RX Optical Link LED 1 indicates the optical signal status of channels 1-8. RX Optical Link LED 2 indicates the optical signal status of channels 9-16. RX Optical Link LED 3 indicates the optical signal status of channels 17-24. RX Optical Link LED 4 indicates the optical signal status of channels 25-32.

rContact Closure Activation LEDs: Not used.

sData Activity LEDs: Not used.

tVideo Present LEDs 1-32:Light green on a per-channel basis to indicate that the incoming video signal is present on the channel. Light red on a per-channel basis to indicate that the incoming video signal is not present on the channel (video loss).

For troubleshooting information relating to the front-panel LEDs, refer to Troubleshooting on page 15.

6

C2652M (1/08)

Image 6
Contents FT8332/FR8332 Fiber Transmitter Receiver Contents List of IllustrationsList of Tables Important Safety Instructions Regulatory Notices Radio and Television InterferenceModels Product OverviewDescription Multimode ModelsFront Panel Front Panel of FT8332/FR8332 Unit with BezelRear Panel Illustrates the rear panel of the FT8332/FR8332 unitInstallation Package ContentsShown Actual Size Mounting the TRANSMITTER/RECEIVER Mounting the TRANSMITTER/RECEIVER Into a RackInserting Cage Nuts Rack Front Mounting the TRANSMITTER/RECEIVER to a Wall Connections Pin NumberRemoving the Bezel TroubleshootingTroubleshooting FRONT-PANEL Indicators Video Present LEDSpecifications on RX Optical Link LossSpecifications VideoMultimode 62.5/125 µm Model Number Optical MaximumTransmitter Single-Mode 9/125 µmProduct Warranty and Return Information ISO9001