GENERAL

Power requirement

 

Rating

: AC 110 – 240 V`, 50/60 Hz

Operating

: AC 90 – 260 V`, 50/60 Hz

Power consumption

: 24 W

Temperature

 

Operating

: 5°C to 40°C

Storage

: –20°C to 60°C

Operating position

: Horizontal only

Dimensions (WxHxD)

: 400 x 94 x 340 mm

Weight

: 3.3 kg

Format

: VHS standard

Maximum recording time

 

(SP)

: 240 min. with E-240 video

 

cassette (PAL/MESECAM)

 

: 160 min. with T-160 video

 

cassette (NTSC)

(LP)

: 480 min. with E-240 video

 

cassette (PAL/MESECAM)

(EP)

: 480 min. with T-160 video

 

cassette (NTSC)

VIDEO/AUDIO

 

Signal system

: PAL-type colour signal and

 

CCIR monochrome signal,

 

625 lines 50 fields

 

: NTSC colour and EIA

 

monochrome signals,

 

525 lines/60 fields

Recording system

: DA-4 (Double Azimuth)

 

head helical scan system

Signal-to-noise ratio

: 45 dB

Horizontal resolution

: 250 lines (PAL/MESECAM)

 

: 220 lines (NTSC)

Frequency range

: 70 Hz to 10,000 Hz

 

(Normal audio)

 

20 Hz to 20,000 Hz

 

(Hi-Fi audio)

Input/Output

: RCA connectors

 

(IN x 2, OUT x 1)

 

 

 

S

PECIFICA

T

IONS

 

TUNER/TIMER

 

 

 

 

 

TV channel storage

 

 

 

 

 

capacity

: 99 positions (+AUX position)

 

Tuning system

: Frequency synthesized tuner

 

Channel coverage

: VHF (Low) 42 – 175MHz

 

 

 

 

(High)175 – 470MHz

 

 

 

UHF 470 – 870MHz

Aerial output

: UHF channels (Adjustable

 

 

 

E32 – E40)

Memory backup time

: Approx. 6 months.

 

 

 

Estimated figure based on

 

 

 

supplied fresh battery; actual

 

 

 

performance may differ.

 

ACCESSORIES

 

 

 

 

 

Provided accessories

: RF cable,

 

 

 

Infrared remote control unit,

 

 

 

"R6/UM-3" battery x 2,

 

 

 

Lithium battery CR2025,

 

 

 

Conversion plug*

*Not provided in certain areas.

Specifications shown are for SP mode unless otherwise specified.

Design and specifications subject to change without notice.

Image 40
Contents HR-J747MS HR-J647MS Safety Precautions Do not place the recorderCheck Contents Installing Your NEW Record ER ENBasic Connections Situate RecorderAuto Set Up Start Auto SET UPDuring Auto Set Up Nitial Sett IngsVideo Channel Set Select Language Select Television System Clock Set Access Function SET Access O.S.D. ScreenENABLE/DISABLE On-Screen DisplaysBasic Playback Load a CassettePoint Start PlaybackActivate HIGH-SPEED Search Playback FeaturesPause During Playback Adjust Tracking Manually Return to Automatic TrackingActivate Repeat Playback Activate Wide QualityActivate Index Search SET Counter MemoryActivate Counter MemoryTape Position Indicator Soundtrack SelectionBasic Recording Recording Features Engage Simulcast Mode Make ConnectionsChoose FM Broadcast Select TV ProgrammeS.T. Picture System RecordingPlayback Timer ProgrammingEngage RECORDER’S Timer Mode TimerAuto SP/LP Timer Engage Auto SP/LPAccess Programme EN Timer RecordingRevise Programme InformationUnplug Vcrs Power SET Remote ControlPlug in Power Cord Turn VCR Power onEdit To Or From Another Video Recorder Input ModeEditing SET RECORDER’S Input Mode Edit From a CamcorderStart Camcorder Start RecorderSetting Of The Colour System Select Buttons Mode DisplayMode Description Off-Air RecordingPlayback equipment Tape-To-Tape EditingDubbed tape Access Tuner SET Screen Select Auto CH SET ModeSelect TV System Tuner SETAccess Tuner SET Select Position ScreenSelect Band SET Desired StationDelete a Channel EN Tuner SETSwap Channel Positions Fine-Tuning Channels Control Your TV Using Additional Buttons SET TV Brand CodeTRY Operating TV EN Remote CON TrolTroubleshooting E N PowerTimer again OubleshootingOther Problems Questions and Answers Index Front ViewDisplay Panel Installing Batteries How To UseIons Memo HR-J747/647MS