JVC HR-J261MS Access Main Nenu Screen, SET Mode, Tape Position Indicator, Picture Control

Page 15

Next Function Memory

The Next Function Memory "tells" the recorder what to do after rewinding. Before continuing, ensure that the recorder is in the Stop mode.

a– For Automatic Start Of Playback After Tape Rewind...

...press REW, then press PLAY within 2 seconds.

b– For Automatic Power Off After Tape Rewind...

...press REW, then press within 2 seconds.

c– For Automatic Timer Standby After Tape Rewind...

...press REW, then press TIMER within 2 seconds.

NOTE:

It is not possible to select the Automatic Timer functions if the cassette's record safety tab is removed.

Tape Position Indicator

The tape position indicator

 

 

 

 

 

 

 

 

 

appears on screen when, from

 

 

 

 

 

 

 

 

 

the Stop mode, you press FF,

 

 

 

 

 

 

 

 

 

REW or perform an Index

 

 

 

 

 

 

 

 

 

Search. The position of "5" in

 

 

 

 

3

 

 

 

relation to "0" (beginning) or "+"

 

0

+

 

+

+

 

 

(end) shows you where you are

 

 

 

 

1:23:45

 

 

on the tape.

 

 

 

 

 

 

 

 

 

"O.S.D." (pg. 8) must be

 

 

 

 

 

 

 

 

 

set to "ON", or the indicator

 

 

 

 

 

 

 

 

 

will not appear.

Beginning

 

 

 

End

NOTE:

Depending on the type of tape used, there may be times when the indication is not correct.

EN15

Picture Control

This feature helps you to adjust the playback picture quality according to your preference. *The default setting is "AUTO."

 

ACCESS MAIN NENU

 

 

SCREEN

 

 

1 Press MENU.

 

 

 

ACCESS FUNCTION SET

 

2

SCREEN

 

 

Place the pointer next to "FUNCTION SET" by pressing

PUSH JOG , then press OK or PUSH JOGÞ.

 

 

 

 

SELECT PICTURE CONTROL

 

SET MODE

 

 

 

Place the pointer next to

FUNCTION SET

 

 

"PICTURE CONTROL" by

 

 

 

 

3 pressing PUSH JOG ,

B.E.S.T.

ON

PICTURE CONTROL

AUTO

 

then press OK or PUSH

AUTO TIMER

OFF

 

JOGÞto select the

O.S.D.

ON

 

desired mode.

AUTO SP=LP TIMER

OFF

 

[5/°] =

 

 

AUTO*: Normally select

 

 

"AUTO."

[MENU] : EXIT

 

 

 

 

 

It automatically adjusts the picture quality.

*When the B.E.S.T. function is set to "OFF" (pg. 18), you can only select "NORM" instead of "AUTO."

EDIT: Select when you dub tapes.

SOFT: Select when you want to soften the picture.

SHARP: Select when you want to sharpen the picture.

NOTES:

When you select "EDIT", "SHARP" or "SOFT", the selected mode will not change until you select again.

When you select "EDIT" to dub tapes, be sure to select "AUTO" (or "NORM" when the B.E.S.T. function is set to "OFF") after you finish dubbing the tapes.

RETURN TO NORMAL

SCREEN

4 Press MENU.

NOTE:

Select "EDIT" when you are dubbing tapes. Refer to page 24, 25.

Image 15
Contents HR-J267MS HR-J261MS Safety Precautions Auto Head CleanerDo not place the recorder Connect Recorder to Mains Check ContentsBasic Connections Situate RecorderEN I Nitial Sett Ings Access Video Channel SET ModeVideo Channel Set Select TV SystemSET SET Video ChannelFinish Video Channel SET Finish Video ChannelSET Date Auto Set UpSelect Language SET TimePress OK or Push JOG Þ During Auto Set UpStart Auto Channel SET Major Countries TV SystemTurn on the Recorder Access Main Menu ScreenENABLE/DISABLE ON-SCREEN Display On-Screen DisplaysSelect Language Access Initial SET ScreenPress Push JOG %Þto place the pointer next to Clock SetPress Press MenuStart Playback Basic PlaybackLoad a Cassette PointActivate HIGH-SPEED Search Playback FeaturesSearch PlaybackManual Tracking Adjust Tracking ManuallyReturn to Automatic Tracking Activate Instant ReviewIndex Search Activate Index SearchActivate Repeat Playback EN PlaybackPicture Control Access Main Nenu ScreenSET Mode Tape Position IndicatorBasic Recording Select Channel to Watch Recording FeaturesReset Counter Engage ITR ModeEN Recording Access Main Menu ScreenS.T. Picture System Return to NormalRecording PlaybackOr press Record on the recorder Enter Programme Date Express Timer ProgrammingTimer Recording Start TimeTimer Mode Return to NormalEngage Recorders Check, Cancel And Replace Programmes Disengage Timer ModeCancel or Replace a Programme Return to Timer ModeAuto SP→LP Timer Auto TimerReturn to Normal Screen Edit To Another Video Recorder Source player Edit From a Camcorder Or Another Video RecorderSET Recorders Input ModeOff-Air Recording Setting Of The Colour System Select ButtonsMode Display Mode DescriptionPlayback equipment Tape-To-Tape EditingRecorded tape HR-J267MS/HR-J261MS Recorded tapeAuto Channel Set ModeSelect TV System Tuner SETSET Desired Station Access Tuner SETAccess Channel List Select PositionSwap Channel Positions Access Channel ListEN Tuner SET Delete a ChannelFINE-TUNE Fine-Tuning ChannelsTry manual tracking. pg TroubleshootingIf youre using the RF OUT connec- tion Press Play to turn the indicator off Check the cassetteRecording Timer againNew one. pg OubleshootingPlayback Recording Questions and Answer S E NFront View IndexDisplay Panel Prog +/-,TV VOL +/-, TV Muting Remote ControlSpecification S HR-J261MS