JVC BR-DV600EA, BR-DV600UA manual Backup Recording Function 12 RS-232C Interface, Command tables

Page 20

11 BACKUP RECORDING FUNCTION

12 RS-232C INTERFACE

Long-time series recording is possible by connecting other DV recorders in series.

5Backup recording

Source VCR

DV camcorder

5Operation

1. Start recording with the source VCR.

* Be sure to start from the beginning of the tape.

12-1 Command tables

This section provides information on programming VCR operations via the RS-232C interface. Basic table

GY-DV500/DV550 or JVC DV camcorder

2. Recording with this unit starts around the time when the

tape in the source VCR ends.

• Recording starts at the time set with the No. 362

<BACK UP REC TIMING> menu switch.

0

0 1 2 3

1

2

3

4

5

6

7

8

9

A

B

C

D

E

F

Complete

Error

Cassette

 

Not

 

 

 

ACK

NAK

 

 

 

 

 

Out

 

Target

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Play

Fwd Shtl

Fwd Shtl Fwd Shtl

Fwd Shtl

Stop

 

 

 

 

 

 

 

 

 

x2

x0.2

Still

x10

 

 

 

 

 

 

 

 

 

 

 

Clear

CueUp

 

 

 

In Shift

In Shift

Out Shift

Out Shift Rev Shtl

Rev Shtl

Rev Shtl

RevShtl

RevShtl

 

IEEE 1394 connection

When you don’t need backup, set the No. 362

 

<BACK UP REC TIMING> menu switch to “OFF”.

The backup recording function records images from

 

the source VCR on this unit. When backup

 

recording starts, continue shooting with the source

4Enter

5 In Entry

6

7

Error

with Data

 

 

 

+

+

x1

x2

x0.2

Still

Still

 

 

 

x10

Out Entry

In Flag

Out Flag

In Flag

Out Flag

Clear

 

Go-to

Go-to

Memory

Memory

 

 

 

Reset

Reset

Recall

Recall

 

In

Out

Search

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Status

 

 

 

 

 

 

 

 

 

 

 

 

 

Sense

 

 

 

 

 

 

 

DV

 

 

 

IN/OUT

COMPONENT

 

VIDEO

AUDIO

LINE

 

 

CH 1/3 CH 2/4

Y/C

 

 

IN

IN

R-Y

B-Y

IN

 

Y

 

 

 

 

 

OUT

OUT

 

 

OUT

 

 

 

MONITOR

 

 

 

OUT

VCR.

8

Date

Clock

Preset

Preset

 

9

 

 

OUT

IN1 REMOTE2

SYNC IN

SERIAL

TIMER

DC 12V

Backup VCR

BR-DV600UA/EA

When this unit is connected to a DV camcorder

(GY-DV500/DV550) via the IEEE 1394, a long-time

recording is possible by starting recording in this unit

around the time after the recording tape in the source VCR

ends.

 

A

Standby

Standby

Preroll

On

Off

 

 

BCueUp

with Data

C

Auto Edit

 

Review

D

 

 

 

E

TC

UB

CTL Data

Preset

Preset

Preset

 

F

 

 

 

Eject

In Data Preset

 

 

 

 

 

 

 

Ff

Rew

Fwd Field Rev Field

 

 

 

 

 

 

 

 

Step

Step

 

 

 

 

 

 

 

 

 

 

 

 

Fwd Shtl

Rev Shtl

 

 

 

 

 

 

 

Date Data

Clock Data

 

 

 

 

 

 

 

 

Sense

Sense

 

 

 

 

 

 

 

 

 

 

Full-EE

EE Off

 

 

 

 

Rec

Rec

Adb

Adb

 

 

On

 

 

 

 

Pause

Pause

 

 

 

 

 

 

 

 

 

 

 

 

Ssf Data

Preroll

Status

Tc Data

CTL Data

In Data

Out Data

UB Data

JVC Status

 

 

 

Sense

Tm Sense

Sense

Sense

Sense

Sense

Sense

Sense

Sense

 

 

Out Data

Edit

Preroll

Timer Mode

 

 

 

 

 

Memory

 

 

Preset

Preset

Tm Preset

Select

 

 

 

 

 

Sw Preset

 

 

 

 

JVC Tbl 1

Basic

JVC Tbl 2

 

Rec/Dub

Vtr Ind

 

 

 

 

 

 

Select

Tbl Select

Select

 

Request

 

 

 

 

 

 

 

 

 

 

 

 

5Preparation

• Connect the [DV] connector of the source VCR to the

[DV IN/OUT] connector of this unit.

• Set the [REMOTE/LOCAL] switch to “REMOTE”.

JVC table-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

2

3

4

5

6

7

8

9

A

B

C

D

E

F

0

Complete

Error

Cassette

 

Not

 

 

 

 

ACK

NAK

 

 

 

 

Out

 

Target

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5Menu switch setting

No. 050 <REMOTE SELECT> ... Select any setting from

IEEE 1394, IEEE

1394 + RS422A, JVC

BUS + IEEE 1394 and

JVC BUS + RS422A +

IEEE 1394.

No. 108 <VIDEO INPUT SELECT> ... IEEE 1394

No. 362 <BACK UP REC TIMING> ...

When the length of the recording on the tape in

2 3

4Enter

5 In Entry

6

7

8

9

Clear

Error

Out Entry

 

 

 

 

 

 

 

 

Play

Stop

 

 

 

 

In Shift

In Shift

Out Shift

Out Shift

 

Still

 

 

 

 

+

+

 

 

 

 

 

 

 

In Flag

Out Flag

In Flag

Out Flag

Clear

 

Go-to

Go-to

Memory

Memory

Reset

Reset

Recall

Recall

 

In

Out

Search

 

 

 

 

 

 

 

 

Status

 

 

 

 

 

 

 

 

 

Sense

 

 

 

 

Rom

Operate

Operate

 

Version

On

Off

 

 

 

Date

Clock

 

 

Preset

Preset

the source VCR is:

 

 

30 minutes: 25MIN

 

60 minutes: 55MIN

 

80 minutes: 75MIN

No. 460 <TC DUPLICATE> ...

OFF

*Video input can also be switched with the switch on the front panel.

 See “Recording preparation” on page 26.

A

Standby

Standby

Preroll

Eject

 

 

 

 

On

Off

 

 

 

 

 

 

 

 

 

 

 

B

 

 

Play After

 

 

Fwd Shtl Rev Shtl

 

 

 

 

CueUp

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

Full-EE

EE Off

 

 

 

 

 

 

On

 

 

 

 

 

 

 

 

 

 

D

 

Device Type

 

Memory

Tape Rem

 

Status

Tc Data

 

 

Request

 

Sw Sense

Sense

 

Sense

Sense

E

 

 

CTL Data

In Data

Out Data

 

Timer Mode

 

 

 

Preset

Preset

Preset

 

Select

 

 

 

 

 

 

F

 

 

 

 

 

JVC Tbl 1

Basic

JVC Tbl 2

 

 

 

 

 

Select

Tbl Select

Select

 

 

 

 

 

 

 

Ff

Rew

Rec

Rec

Adb

Pause

 

 

CTL Data

 

 

Sense

 

 

Rec/Dub

Vtr Ind

 

Request

 

 

 

Fwd Field Rev Field

Step

Step

 

Date Data

 

Sense

Adb

 

Pause

 

JVC Status

 

Sense

 

Memory

 

Sw Preset

 

Clock Data Sense

36

37

Image 20
Contents Thank you for purchasing this JVC product Before operating this unit, please readInstructions carefully to ensure Best possible performance For Customer UseMeters Port CableLength Safety Precautions For Your Safety AustraliaThis unit should be used with 120 V AC only Mains Supply AC 230 V `Introduction Major featuresMaintenance Introduction PrecautionsPrecautions for use of head cleaning tape # Y/C in connector Rear panelCONTROLS, Connectors and Displays On-screen displayLCD display Slave NDF HoldReference sync signal ConnectionsAudio system connections OutputsRemote connector Power socketsOther connections Editing system examplesBR-DV600UA Edit adjust settingBR-DV600UA/EA Menu Switches Menu switch organizationMenu switch group select screen Menu switch setting screenMenu Switches Menu switch detailsEdit Adjust Auto REW AT TimerBattery Select Remote FF/REW ModePreparation PreparationRecording RecordingPlayback Repeat play Playback preparationExternal TIMER-START Function PresetTime Code DisplayTime Code Playback time code Super Scene Finder FunctionPlayback Backup Recording Function 12 RS-232C Interface Command tables12-2 RS-232C specifications 12-3 RS-232C commandsVCR operation commands 12 RS-232C InterfaceCommands Description Information gathering sense commandsSetting preset commands Error-related commands Contents of Status SenseContents of JVC Status Sense Menu switch setting command Menu switch check commandED Memory SW Preset ComponentTroubleshooting Operation SolutionDEW indicator lights Counter displayOptional equipment SpecificationsOther problems

BR-DV600EA, BR-DV600UA specifications

The JVC BR-DV600UA and BR-DV600EA are professional digital video recorders that have gained recognition in the broadcasting and media production industries due to their advanced features and reliability. These models are tailored for video professionals who require high-quality video capture and playback capabilities.

One of the standout features of the BR-DV600 series is its compatibility with various formats, including DVCAM, DVCPRO, and standard DV, making it an adaptable option for many users. The ability to record in multiple formats allows for flexibility in production workflows, accommodating diverse client needs and project requirements.

The BR-DV600UA and BR-DV600EA are equipped with robust transport mechanisms, ensuring stable and accurate playback. This reliability is crucial in professional settings where quality cannot be compromised. The units are designed to withstand the rigors of daily use, featuring durable construction that protects the internal components.

A notable technology integrated into these recorders is JVC's innovative digital signal processing, which enhances the overall video quality. This technology ensures improved color reproduction and finer detail, resulting in footage that meets the high standards of professional productions. Furthermore, the devices support real-time editing capabilities, which allow for seamless transitions and effects during the recording process, thus expediting post-production.

Another key characteristic of the BR-DV600 series is its comprehensive connectivity options. The recorders come equipped with multiple input and output interfaces, including FireWire (IEEE 1394), composite, and SDI connections. This versatility enables users to integrate the units into various production environments easily, whether for live events, studio recordings, or field productions.

User-friendly operational design is also evident in these models. The intuitive interface, clear LCD displays, and accessible controls facilitate ease of use, allowing operators to focus on their craft without being hindered by complicated setups. The built-in editing functions further enhance usability, enabling quick adjustments and refinements on the fly.

In summary, the JVC BR-DV600UA and BR-DV600EA digital video recorders stand out in the professional video market due to their format versatility, advanced digital processing technologies, reliable construction, and user-friendly designs. These features collectively make them an excellent choice for videographers, broadcasters, and production companies seeking dependable and high-quality recording solutions.