6.1Switch Firmware Issues

The following known problems apply to the current release of the switch firmware for this product:

4899178: Blade network traffic is only allowed through the IP filter on the VLAN configured as the management VLAN.

The management VLAN is the VLAN that has been assigned an IP address to allow network access to the switch’s management interfaces (by default this is VLAN2). Other VLANs can be assigned to the NETMGT port to allow blades to talk to particular hosts on the management network. The usual way to do this would be to put particular blades and particular hosts that are on the management network onto a tagged VLAN that is separate from the management VLAN. However, the switch’s packet filter will not forward any traffic from the blades to the management network unless that traffic is for the management VLAN. This is a problem that will be fixed in the next release of the switch firmware. It means that traffic from the blades will not be seen by hosts on the management network that are external to the chassis (in other words, only other blades in the chassis will see the traffic) unless the blade, the switch, and the external hosts involved are all on the management VLAN. Note that the configurations for multiple tenants described in Chapter 7 of the Sun Fire B1600 Blade System Chassis Software Setup Guide will not be possible until this problem has been fixed.

4854587: It is possible that the System Controller will reset the switch when the

switch is executing commands that require unusually intensive processing: The SC continuously polls the switch for status as part of the system healthcheck.Itis theoretically possible that, while executing commands requiring unusually intensive processing, the switch will be unable to respond to the SC’s status request within the timeout period because it must first complete execution of a process-intensive command.

This should not happen during normal operation. The problem was observed when a user sent a sequence of lengthy commands (for example, commands adding many VLANs to a port) to the switch without waiting for the prompt between each command. This filled the switch’s input buffer and blocked the status poll messages.

To avoid the problem, always wait for one command to complete before issuing another command on the CLI. If you are using scripts this is especially important.

6-2Sun Fire™ B1600 Chassis and B100s, B100x, and B200x Blade Product Notes • May 2004

Image 50
Contents Page Page Contents Sparc Solaris Contents Page Documentation and Miscellaneous Information Using N1 Provisioning Software Upgrading the Bios on a B200x Server BladeBefore Installing Solaris x86 Onto a Blade Miscellaneous InformationUsing the Sun Fire B10n Content Load Balancing Blade Downloading New Firmware for Chassis ComponentsDocumentation in this Release Documentation Errata Page Linux Installing Linux Onto a B100x or B200x Blade Upgrading the Bios on B200x Server Blades To Upgrade the BiosBlade prompt returns when the update is complete B100x and B200x Linux Server Blade Issues Issues Affecting the B200x Server Blade OnlyIssues Affecting the B100x Server Blade Only Preparing to Install Solaris x86 Onto a Blade SolarisSolaris x86 Drivers and Documentation Overview of the Solaris x86 Installation Process # mkdir -m 755 /var/tmp/blades Proceed to Creating a Network Install Server on Creating a Network Install Server # ./modifyinstallserver -d installdirpath Page Need Support for Soft Poweroff in Solaris Workaround Workaround Page Error Messages That Can be Safely Ignored Consconfig complains on servers with no frame bufferPage Solaris x86 Other Issues Acpi Resource Conflicts Unnecessarily Reported1The Network Interfaces on a B200x Blade Base MAC + 1, snet1 Solaris x86 Page Sparc Solaris Installing Sparc Solaris Onto a B100s Server Blade B100s Sparc Solaris Server Blade Issues# share -F nfs /cdrom/solaris8hw1202suppcd Installation of SUNWidecr failed System Controller Upgrading the System Controller SC Firmware Set up a new user name and password for yourself System Controller Software Issues System Controller FirmwareScreset -x -y sn Scremovefru -y psn scpoweron psn System Chassis’s Integrated Switch Switch Firmware Issues Console#configure Consoleconfig#vlan database Consoleconfig#no vlan vlanid System Chassis’s Integrated Switch Page Console#configure Page Consoleconfig#no bridge-ext gvrp Aggregated Links Switch-to-switch Tagged Vlan Trunk Connections Setting up a Tagged Vlan Trunk With Cisco Switches