4871779: Blades are unable to receive multicast packets when IGMP querying is enabled.

Multicasting on the switch does not work correctly if the IP address for the switch is not configured. This is only likely to be the case if the IP address is configured by DHCP and the DHCP process has failed for any reason. If necessary, you can work around the problem by specifying an IP address for the switch manually:

Console#configure

Console(config)#ip address ip address netmask

4885056: The switch does not have ingress filtering enabled by default.

By default ingress filtering is set to disabled. This allows packets from VLANs other than the VLANs explicitly enabled on each port to pass through the switch. This is a security risk. To enable ingress filtering on the switch, you must enable it on each port individually. The following example demonstrates how to enable it for NETP0. Repeat the commands for each port (from NETP1 through NETP7 and SNP0 through SNP15) and aggregate link (port-channel):

Console#configure

Console(config)#interface ether NETP0

Console(config-if)#switchport ingress-filtering

4894936: Auto-negotiation and speed/duplex mode cannot be configured on the NETMGT port

The NETMGT port’s speed and duplex mode are fixed at 100Mbps and full duplex. This is not manually configurable. However, it is possible to connect to the NETMGT port using a 10BaseT full- or half-duplex connection, or a 100BaseT full- or half-duplex connection. If you do this, the switch’s internal hub negotiates the speed and duplex mode automatically with the interface at the other end of the connection. If you attempt to set the speed and duplex mode for NETMGT manually, you will receive an error message to the effect that the interface ethernet NETMGT speed-duplexcommand failed. In future releases of the switch firmware the error message will explain that NETMGT cannot be manually configured using this command.

4780304: Adding a port to the forbidden VLAN list sometimes fails to remove the VLAN from that port’s VLAN list

This error is only seen when the port you are trying to add to the forbidden list is the last VLAN on that port’s VLAN list (apart from the native VLAN, which can never be removed). Firmware that fixes this problem is now available from http://sunsolve.sun.com (patch number: 114783-xx).

Chapter 6 The System Chassis’s Integrated Switch 6-3

Image 51
Contents Page Page Contents Sparc Solaris Contents Page Documentation and Miscellaneous Information Miscellaneous Information Upgrading the Bios on a B200x Server BladeBefore Installing Solaris x86 Onto a Blade Using N1 Provisioning SoftwareDownloading New Firmware for Chassis Components Using the Sun Fire B10n Content Load Balancing BladeDocumentation in this Release Documentation Errata Page Linux Installing Linux Onto a B100x or B200x Blade To Upgrade the Bios Upgrading the Bios on B200x Server BladesBlade prompt returns when the update is complete Issues Affecting the B200x Server Blade Only B100x and B200x Linux Server Blade IssuesIssues Affecting the B100x Server Blade Only Solaris Preparing to Install Solaris x86 Onto a BladeSolaris x86 Drivers and Documentation Overview of the Solaris x86 Installation Process # mkdir -m 755 /var/tmp/blades Proceed to Creating a Network Install Server on Creating a Network Install Server # ./modifyinstallserver -d installdirpath Page Need Support for Soft Poweroff in Solaris Workaround Workaround Page Consconfig complains on servers with no frame buffer Error Messages That Can be Safely IgnoredPage Solaris x86 Acpi Resource Conflicts Unnecessarily Reported Other Issues1The Network Interfaces on a B200x Blade Base MAC + 1, snet1 Solaris x86 Page Sparc Solaris B100s Sparc Solaris Server Blade Issues Installing Sparc Solaris Onto a B100s Server Blade# share -F nfs /cdrom/solaris8hw1202suppcd Installation of SUNWidecr failed System Controller Upgrading the System Controller SC Firmware Set up a new user name and password for yourself System Controller Firmware System Controller Software IssuesScreset -x -y sn Scremovefru -y psn scpoweron psn System Chassis’s Integrated Switch Switch Firmware Issues Console#configure Consoleconfig#vlan database Consoleconfig#no vlan vlanid System Chassis’s Integrated Switch Page Console#configure Page Consoleconfig#no bridge-ext gvrp Aggregated Links Switch-to-switch Tagged Vlan Trunk Connections Setting up a Tagged Vlan Trunk With Cisco Switches