The fi replace should be framed using 2x4 lumber. For the header and cripple studs above the fi replace it is recommended to use steel. The fireplace must be secured to the floor in all cases. Use the pallet packing brackets to secure to the fl oor. If ducting is to be installed, the minimum enclosure ceiling height is 84". Without ducting, the ceiling height may be brought down to a minimum of 72". However a fi replace enclosure with a height less than 84" must be provided with suffi cient air circulation to avoid a fi re hazard. Install ventilation grilles (minimum openings of 40 sq. inches) at both fl oor and ceiling levels of the enclosure.
Do not place insulation into the enclosure around the fi replace or the chimney. Combustible framing materials must not be closer than 6" from the side of the unit and 5" from the top of the unit.
FIGURE 7c: Finishing Requirements
FINISHING
Clearances to fi nishing materials: 63/4" minimum of
Objects placed in front of the fi replace must be kept a minimum of 48" away from the front face of the unit.