For quick setup of VisualServer, the administrator can utilize the default CONFIG.INI that may be downloaded from the FTP daemon of VisualServer. To log into the FTP daemon, enter “root” as the user name and the same password used when connecting to the Web server. The serial number of VisualServer is the password for the initial access.

Then administrators only need to modify necessary fields and then upload the file to VisualServer with the file name “CONFIG.INI”. To reduce error in interpretation, it is recommended that the downloaded template CONFIG.INI be modified using the options following each item in the sample below. The file will include seven categories: [SYSTEM], [NETWORK], [VIDEO], [SERIAL], [ALERT],and [LAYOUT]. The category name in brackets should be in upper case. The item name in angle braces should be in lower case. Some items related to disable/enable should use the keywords “YES”/“NO”. The number zero entry in <user name> and <user password> is for the administrator, i.e. “root”.

Since the password when logging into FTP is not encrypted, it is recommended to use the Web instead of FTP to configure the system afterwards. If some parameters other than the network or camera drivers are changed, administrators can set <reset system> to NO to avoid resetting the system. It will automatically return to YES during the next downloading of CONFIG.INI.

A sample CONFIG.INI is attached below. The italic text following each line describes the format of the field and the bold italic characters are the possible values of each field.

******* sample file **********

VisualServer Initial Configuration File

[SYSTEM]

 

<reset system>

 

YES

or NO

<host name>

 

VisualServer

String shorter than 40 characters

<serial number>

 

 

 

 

 

 

66

www.vivotek.com

T: 886-2-22404099

F: 886-2-22404097

Image 67
Contents VisualServer Before You Use Table of Contents Web FTP Appendix Package Contents 886-2-22404099 886-2-22404097 RCA audio input Physical DescriptionFront Panel BNC video inputEthernet 10/100 socket Rear PanelCOM port General I/O terminal block Status LEDs Power adapter Restore buttonHow to Install Ethernet Environment Hardware installationCable connection Power on Easy way with installer program Software configuration886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 Manual way with existing programs First access to VisualServer 886-2-22404099 886-2-22404097 Modem Environment Cable connection Install a new modem 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 Setup a new connection 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 First access to VisualServer 886-2-22404099 886-2-22404097 How to Use Authentication 886-2-22404099 886-2-22404097 Main screen with camera view Primary user’s capabilityPTZ camera control Client Setting Url http//VisualServer/client.html System configuration System parameters 886-2-22404099 886-2-22404097 User group administration Network settings 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 Modem for software installation Video codec parameters 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 Motion detection 886-2-22404099 886-2-22404097 PTZ camera configuration 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 Modem and dialup settings 886-2-22404099 886-2-22404097 Application 886-2-22404099 886-2-22404097 Homepage layout settings One-shot fast configuration via FTP Read only string For teal For blank, 1 for default image or 2 for loading from URL Standard IP format or string shorter than 40 characters Integer less than 3 representing half, halfx2, normal Or RS485 For FTP, 1 for email Viewing system log Restore factory default settingsClear data path for proprietary commands Advanced functionsCustomizing homepage images Uploading snapshots periodically to an external FTP serverSoftware revision upgrade Uploading the configuration file886-2-22404099 886-2-22404097 Query status of digital inputs System core debuggingMonitor changed status of digital inputs Stop information dumpingSet digital outputs Skip installation during the next bootReset network for new settings Reset systemMove motorized camera in PTZ direction URL commands of VisualServerCapture update Snapshot of Jpeg image Preset/Recall camera positionRestart system Clear data mode serial port driverURL System configuration URL General format of command URLSystem resource URL Network configuration URL Security configuration URLVideo configuration URL Image quality configuration URL Camera preset configuration URL Camera Configuration URLCamera custom command configuration URL Modem configuration URL Custom camera configuration URLApplication configuration URL Homepage layout configuration URL Appendix Post procedureFrequently asked questions 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 Networking Technical specificationsElectromagnetic Compatibility EMC