Set digital outputs
To set digital output to connect NO with COMMON, type "DO=L".
To set digital output to connect NC with COMMON, type "DO=H".
Erase snapshots stored in Flash memory
Typing "erase image" will clear all snapshots saved in Flash.memory.
Erase logo and graphic buttons
Typing "erase graph" will clear all images used on the homepage. If no new images are uploaded, the system will switch to text mode and use default images instead.
Skip installation during the next boot
Typing "lock" will inform VisualServer to fix current network settings. It need not wait for installation during the next boot.
Reset network for new settings
Typing "unlock" will make VisualServer give up current settings and wait for installation.
Restore factory default settings
Typing "clear" will make VisualServer restore factory settings but not restart. To validate new settings, type "reset" to make the system restart.
Reset system
Typing "reset" will make VisualServer perform a software reset.
80
www.vivotek.com
T: 886-2-22404099
F: