Vivotek VS3102 user manual System core debugging, Monitor changed status of digital inputs

Page 80

Telnet

VisualServer has a Telnet daemon for administrators to access some seldom used functions. Using any general terminal program to connect to VisualServer will prompt the user for a password. Username is not requested here since only administrators can access the Telnet daemon. The password is as same as that used for web access. After logging in, type "help" for the command list. If "debug" or "dinote" is not executed, Telnet will disconnect automatically after being idle for 1 minute.

System core debugging

General activities are recorded into SYSTEM.LOG continuously, but information about abnormal status is not. To look deep into the core debugging information, administrators may type the “debug” command. This will cause VisualServer to start dumping the detailed debugging information while the system is running. This is useful to examine if any error has occurred when the system operates abnormally. The stored information will be cleared automatically after the dump. VisualServer will continue to dump new messages unless the connection is broken. If Telnet is not connected, any messages will be stored until administrators re-login.

Monitor changed status of digital inputs

Typing "dinote" will make VisualServer send the current status of digital input. After that VisualServer will continuously monitor DI status and send messages only when the state has changed. For example, after typing "dinote" the terminal will display

DI=L

DI=L

and if DI changes to H, terminal will display only DI=H

Stop information dumping

Typing "stop" will cease dumping debug information and digital input status.

Query status of digital inputs

Typing "diquery" will display the status of digital input once.

79

www.vivotek.com

T: 886-2-22404099

F: 886-2-22404097

Image 80
Contents VisualServer Before You Use Table of Contents Web FTP Appendix Package Contents 886-2-22404099 886-2-22404097 Physical Description Front PanelBNC video input RCA audio inputCOM port Rear PanelEthernet 10/100 socket General I/O terminal block Status LEDs Restore button Power adapterHow to Install Cable connection Hardware installationEthernet Environment Power on Software configuration Easy way with installer program886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 Manual way with existing programs First access to VisualServer 886-2-22404099 886-2-22404097 Modem Environment Cable connection Install a new modem 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 Setup a new connection 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 First access to VisualServer 886-2-22404099 886-2-22404097 How to Use Authentication 886-2-22404099 886-2-22404097 Primary user’s capability Main screen with camera viewPTZ camera control Client Setting Url http//VisualServer/client.html System configuration System parameters 886-2-22404099 886-2-22404097 User group administration Network settings 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 Modem for software installation Video codec parameters 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 Motion detection 886-2-22404099 886-2-22404097 PTZ camera configuration 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 Modem and dialup settings 886-2-22404099 886-2-22404097 Application 886-2-22404099 886-2-22404097 Homepage layout settings One-shot fast configuration via FTP Read only string For teal For blank, 1 for default image or 2 for loading from URL Standard IP format or string shorter than 40 characters Integer less than 3 representing half, halfx2, normal Or RS485 For FTP, 1 for email Restore factory default settings Clear data path for proprietary commandsAdvanced functions Viewing system logUploading snapshots periodically to an external FTP server Customizing homepage imagesUploading the configuration file Software revision upgrade886-2-22404099 886-2-22404097 System core debugging Monitor changed status of digital inputsStop information dumping Query status of digital inputsSkip installation during the next boot Reset network for new settingsReset system Set digital outputsURL commands of VisualServer Capture update Snapshot of Jpeg imagePreset/Recall camera position Move motorized camera in PTZ directionClear data mode serial port driver Restart systemURL System resource URL General format of command URLSystem configuration URL Security configuration URL Network configuration URLVideo configuration URL Image quality configuration URL Camera custom command configuration URL Camera Configuration URLCamera preset configuration URL Custom camera configuration URL Modem configuration URLApplication configuration URL Homepage layout configuration URL Post procedure AppendixFrequently asked questions 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 Technical specifications NetworkingElectromagnetic Compatibility EMC