COMMERCIAL MODE
COMMERCIAL MODE
(Continued from previous page)
The value range is 0 to 63, with 63 as the default, which gives the user the full range of volume control, if item 008 MIN VOLUME is also set at 0. Change values with ADJ Left/Right arrow keys. It may be best to set the same value on every 26LH1DC3/4/5.
*Note: The maximum volume level cannot have a value setting lower than the MIN VOLUME level (described previously).
010 - MUTE DISABLE
Enables or disables sound mute function. If set to 1, sound cannot be muted, mute is disabled. If set to 0, sound can be muted.
011 - KEY DEFEAT (Keyboard Defeat)
If set to 1, key defeat prevents the end user from accessing the onscreen menus with the display front
*Note: The menus can always be accessed by pressing MENU on the Installer remote.
015 - SLEEP TIMER
If set to 1, the SLEEP TIMER feature may be used. If set to 0, the Sleep Timer is not available.
016 - EN TIMER (Enable On/Off Timers)
If set to 1, Timer function is available to user. Set to 0 to disable On/Off Timer functions. (Clock must be set in order to use Timers.)
017 - ALARM
Gives the installer the option of making the Alarm function available to the end user. If set to 1, Alarm function is available to end user.
Set to 0 to disable the Alarm function.
*Note: Clock must be set before the Alarm function will work.
021 -
Set to 1 to activate
022 - MAX BLK HRS (Maximum Block Hours) Sets hours from 0 to 99 for the maximum
023 - CAPTION LOCK
Set to 1 to restore previous caption On/Off state after turn Off. If set to 0, captions are always Off at turn On.
(Continued from previous page)
028 - CH. OVERIDE (Channel Override)
If set to 1, the user can select channels with either Channel up/down or by direct keypad entry. If set to 0, only those channels that are added on the channel list can be selected.
029 - OLD OCV (On Command VideoTM)
Set to 1 for operation with systems from On Command Corporation.
030 - ACK MASK
M.P.I. Communication Parameter. Leave at default setting unless changed by
031 - POLL RATE
M.P.I. Communication Parameter. Selects Poll Rate for M.P.I. Leave at default setting unless changed by
032 - TIMING PULSE
M.P.I. Communication Parameter. Leave at default setting unless changed by
034 - CAMPORT EN. (Camera Port Enable)
Set to 1 to enable Video 2 input on display panel. If set to 0, Video 2 input on display panel is not functional.
035 - COMPPORT EN. (Computer Port Enable) Enable/disables display panel HDMI input jack. Set to 0 to disable, set to 1 to enable.
*Note: The setting above is ignored if Installer item 093 RJP AVAIL ABLE, is set to 1.
038 - YPrPb EN. (Rear Component Video Enable) Set to 1 to enable display panel rear Component Video 1 input.
Set to 0 to disable display panel rear Component Video 1 input.
039 - REAR AUX EN. (Rear Aux Enable)
Set to 1 to enable display panel rear AUX (Video 1) input.
Set to 0 to disable display panel rear AUX (Video 1) input.
040 - AUTO CAMPORT
Set to 1 to automatically switch to Camport when equipment is connected to front Video input.
Set to 0 to disable front Video automatic source selection.
*Note: This item must be set to 0 in order to enable item 093 RJP AVAILABLE to be set to 1.
046 - STRT AUX SRCE (Start Aux Source)
Sets the starting AUX source. |
| |
Start source if start channel =0 |
| |
1 = Video1 | 4 = RGB1 | 7 = Video 3 / |
2 = Video2 | 5 = Component 2 255 = Last Aux |
3 = HDMI 1 6 = Component 1
047 - AUX STATUS
Set to 1 for M.P.I. AUX source to be reported as a channel number instead of channel 0. Set to 0 to disable AUX identification change.
Controls M.P.I. status channel response for AUX inputs.
(Continued on next page)
60