Peerless Industries SF 16D manual Installation to Single Wood Stud Wall, Skip to on

Page 4

Installation to Single Wood Stud Wall

WARNING

Installer must verify that the supporting surface will safely support the combined weight of all attached equipment and hardware.

1

Use a stud finder to locate the edges of the stud. Use of an edge-to-edge stud finder is highly recommended. Based

on its edges, draw a vertical line down the stud’s center. Place wall plate (AA) on wall as a template, making sure

that the three mounting holes are over the stud centerline. The top mounting hole should be 2.5" above the desired screen center as shown in figure 1.1. Level plate, and mark the center of the three holes. Drill three 5/32" (4 mm) dia. holes 2-1/2" (65 mm) deep. Make sure that the wall plate is level, secure it using three #14 x 2.5" wood screws (CC) as shown in figure 1.2.

Skip to step 2 on page 7.

WARNING

Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.

Never tighten in excess of 80 in. • lb (9 N.M.).

Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder is highly recommended.

Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Installers are responsible to provide hardware for other types of mounting situations.

AA

CS = center of screen

2.5"

(64 mm)

CS

fig. 1.1

CC

fig. 1.2

4 of 9

ISSUED: 08-02-05 SHEET #: 202-9010-1

Image 4
Contents Models SF 16D Features Accessories Tools Needed for AssemblyTable of Contents Parts List Installation to Single Wood Stud Wall Skip to onInstallation to Double Wood Stud Wall Installation to Solid Concrete or Cinder Block CC DDInstalling Interface Bracket to PLP Adapter Plate 1landscape portraitInstalling Interface Bracket to LC Adapter Plate Mounting and Removing Flat Panel Screen Detail